14 Cleaning
14.2 Cleaning nozzle and spray lance
Rinse the nozzle and spray lance under running water and
dry with a cloth.
If the nozzle is clogged: Clean the nozzle with the cleaning
pin.
14.3 Cleaning the water intake screen
Unscrew the connector (1) of the water connection.
Remove water intake screen (2) from the connector.
Rinse out the water intake screen (2) under running water.
Insert water intake screen (2) into the connector.
Attach the connector (1) and tighten it by hand.
14.4 Cleaning the water filter
The water filter must be disassembled to clean it.
Remove the seal (1) from the filter housing (3).
Take the filter (2) out of the filter housing (3).
Rinse out the seal (1) and the filter (2) under running
water.
Grease the gasket (1) with a fitting grease.
Reassemble the water filter.
0000099071_001
0000098884_001
1
1
2
0000099084_001
1
2
3
0000099083_001

Table of Contents

Other manuals for Stihl RE 100 PLUS CONTROL

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Stihl RE 100 PLUS CONTROL and is the answer not in the manual?

Stihl RE 100 PLUS CONTROL Specifications

General IconGeneral
BrandStihl
ModelRE 100 PLUS CONTROL
CategoryPressure Washer
LanguageEnglish

Related product manuals