Version 127 V / 60 Hz
Fuse (characteristic "C" or "K"): 15 A
Power consumption: 1.5 kW (EU) 2019/1781 §2(2) (j)
Maximum permitted network impedance: 0.15 Ohm
Protection class: II
Degree of of electrical protection: IPX5
Working pressure (p): 7 MPa (70 bar)
Max. permissible pressure (p max.): 10 MPa (100 bar)
Max. water supply pressure (p in max.): 1 MPa (10 bar)
Max. water throughput (Q max.): 7.5 l/min (450 l/h)
Minimum water throughput (Q min.): 5.2 l/min (310 l/h)
Max. suction lift: 0.5 m
Max. water temperature in pressure mode (t in max):
40 °C
Max. water temperature in suction mode: 20 °C
sample inspection
Length: 290 mm
Width: 270 mm
Height: 800 mm
Length of high-pressure hose: 5 m
Weight (m) with accessory attached: 7.5 kg
Versions from 220 V to 230 V / from 50 to 60 Hz
Fuse (characteristic "C" or "K"): 10 A
Power consumption: 1.7 kW (EU) 2019/1781 §2(2) (j)
Maximum permitted network impedance: 0.15 Ohm
Protection class: II
Degree of of electrical protection: IPX5
Working pressure (p): 9 MPa (90 bar)
Max. permissible pressure (p max.): 12 MPa (120 bar)
Max. water supply pressure (p in max.): 1 MPa (10 bar)
Max. water throughput (Q max.): 7.2 l/min (430 l/h)
Minimum water throughput (Q min.): 5.5 l/min (330 l/h)
Max. suction lift: 0.5 m
Max. water temperature in pressure mode (t in max):
40 °C
Max. water temperature in suction mode: 20 °C
sample inspection
Length: 290 mm
Width: 270 mm
Height: 800 mm
Length of high-pressure hose: 5 m
Weight (m) with accessory attached: 7.5 kg
Parameters dependent on pressure have been measured at
an inlet pressure of 0.3 MPa (3 bar).
19.3 Extension Cords
If an extension cord is used, it must have a ground wire and
the wire gage of its conductors must meet the following
minimum requirements – depending on the line voltage and
length of the extension cord:
If rated voltage on the rating label is 220V to 240V:
Cord length up to 20 m: AWG 15 / 1.5 mm²
Cord length 20 m up to 50 m: AWG 13 / 2.5 mm²
If rated voltage on the rating label is 100 V to 127 V:
Cord length up to 10 m: AWG 14 / 2.0 mm²
Cord length 10 m up to 30 m: AWG 12 / 3.5 mm²