EN 
89
             
0478 131 8365 C - EN
Divided mowing area with a pond and a 
free-standing tree
Docking station:
Location (1) directly next to the house A
No-go area:
Installation around the free-standing tree, 
based on a linking section installed at right 
angles to the edge.
Pond:
For safety reasons (specified wire 
clearance), the perimeter wire (2) is routed 
around the pond B.
Wire clearances: (Ö 12.5) 
Clearance to the edge: 28 cm
Clearance to adjoining area that can be 
travelled on (e.g. footpath) with a stepped 
area height of less than +/- 1 cm: 0cm
Around the tree: 28 cm 
Clearance to the pond: 100 cm 
Corridor:
Installation of a corridor (3).  Wire 
clearance: 22 cm (Ö 12.11)
Guide loops:
Installation of two guide loops (4) for using 
the offset drive home function.(Ö 11.13)
Minimum clearance from the corridor 
entrance: 2m
Note the minimum clearance to corners. 
(Ö 12.12)
Programming:
Define the total size of the mowing area, 
program two starting points (5) (close to 
the docking station and in the contorted 
corner near the pond) (Ö 11.14)
Points to note:
Unmown areas, e.g. around the pond must 
be mown manually on a regular basis or 
cut using a suitable lawn trimmer.