EN
89
0478 131 8365 C - EN
Divided mowing area with a pond and a
free-standing tree
Docking station:
Location (1) directly next to the house A
No-go area:
Installation around the free-standing tree,
based on a linking section installed at right
angles to the edge.
Pond:
For safety reasons (specified wire
clearance), the perimeter wire (2) is routed
around the pond B.
Wire clearances: (Ö 12.5)
Clearance to the edge: 28 cm
Clearance to adjoining area that can be
travelled on (e.g. footpath) with a stepped
area height of less than +/- 1 cm: 0cm
Around the tree: 28 cm
Clearance to the pond: 100 cm
Corridor:
Installation of a corridor (3). Wire
clearance: 22 cm (Ö 12.11)
Guide loops:
Installation of two guide loops (4) for using
the offset drive home function.(Ö 11.13)
Minimum clearance from the corridor
entrance: 2m
Note the minimum clearance to corners.
(Ö 12.12)
Programming:
Define the total size of the mowing area,
program two starting points (5) (close to
the docking station and in the contorted
corner near the pond) (Ö 11.14)
Points to note:
Unmown areas, e.g. around the pond must
be mown manually on a regular basis or
cut using a suitable lawn trimmer.