Instructions for recharging
Follow the instructions below:
●
Lift the battery cover (1)
●
Take the plug (2) of the on-board battery
charger and connect it to the power outlet.
●
The green LED (3) begins to flash
●
When charging is completed, the green
LED (3) remains lit.
●
Replace the plug in its housing.
●
Close the battery compartment cover.
WARNING
The red LED (4) indicates that the battery has been
left too long with insufficient charge.
Do not leave the battery with insufficient charge for
longer than 24 hours.
Recharging the battery, spe-
cific for batteries with electro-
lyte recirculation system
CAUTION
The battery is recharged with the forklift off.
DANGER
The battery must be charged in rooms that comply
with the specific regulations on the subject. Refer to
the battery and battery charger manuals to see the
charging procedures, level checks etc, checking
the type of battery (gel, lead etc) and making sure
of the voltage and current delivered. Excessive cur-
rents can damage batteries and cause dangerous
situations. As far as the safety precautions are con-
cerned, follow the instructions given in the battery
manual and those included in "Safety regulations
"of this manual.
Access the upper part of the battery as descri-
bed in the "Internal accessibility" paragraph.
1
1843
2
3
4
B
A
C
2252
Use and operation
4
Recharging the battery, specific for batteries with electrolyte recirculation system
56 45628043302 EN - 11/2021 - 07