Safety
V 152 10 11 Rev.: END
2-7
When replacing individual parts and large assemblies, carefully attach and secure
them to lifting devices in order to minimise the danger which emanates from them.
Use only suitable and technically perfect lifting devices and load suspension devices
which have adequate load-bearing capacity!
Never stand or work under suspended loads!
Do not use aggressive cleaning agents! Use non-linting cleaning cloths!
Dispose of operating and auxiliary materials as well as replacement parts safely and
in an environmentally friendly manner!
2.10
Information on particular types of danger
2.10.1
Electrics
Work on the electrical equipment of the gantry press may be performed by
electricians or instructed personnel under the management and supervision of
electricians in accordance with the rules on electrotechnology!
Before opening the control cabinet, switch off the gantry press using the main switch
and secure with a safety lock to prevent reactivation.
If the electric power supply is defective, immediately switch off the gantry press using
the main switch!
Use only original fuses with the stipulated nominal current!
Electrical components which have to be inspected, maintained or repaired must be
deenergised. Secure operating facilities, which were used for activation, to prevent
unintentional or automatic reactivation (lock away fuses, block disconnector, etc.).
Should any electrical components be active, first check that they are deenergised,
then isolate adjacent energised components. In the case of repairs, ensure that the
safety of design features is not compromised (e.g. do not reduce creepage distances
and air paths nor distances by insulation)!
If work has to be performed on live components (in exceptional situations only!),
request the assistance of an additional person who can actuate the Emergency Stop
pushbutton or the main switch in an emergency. Use insulated tools only.
The electrical system must be properly earthed by means of protective conductor
systems.
Even when the machine has been switched off, certain assemblies can still be live or
charged.
Regularly check cables for damage and, if required, replace.