Ejector plate does not return to its home position
Causes:
Pressing shield is not in the upper limit position.
Rectification Move the pressing shield all the way up in manual mode.
Bale is not ejected
Causes:
Pressing shield is not in the upper limit position
Press chamber door is not opened wide enough
Rectification Move the pressing shield to the upper end position using the
two-handed control.
Open the door (opening angle must be at least 100°)
Information!
If a fault could not be rectified, notify the Technical Service department
at Strautmann Umwelttechnik GmbH (address see Identification data).