15
CONNECTING TO GAS SUPPLY
WARNING: A qualied service technician must connect heater to gas supply.
Follow all local codes.
WARNING: This appliance requires 1/2-inch NPT (National Pipe Thread) inlet
connection to the pressure regulator.
WARNING: Never connect heater to private (non-utility) gas wells. This is com-
monly known as well-head gas.
CAUTION: Never connect heater directly to the natural or propane/LP supply.
This heater requires an external regulator (not supplied). Install the external
regulator between the heater and natural or propane/LP supply.
1.
Apply pipe joint sealant lightly to tting threads. Connect approved exible gas
hose to gas regulator of heater (see Figure 11).
Figure 10 - Attaching Heater Base to Fireplace Floor
NOTE: Never apply pipe sealant to are tting threads.
IMPORTANT: Hold gas regulator with wrench when connecting exible gas hose.
2. Locate masonry screws in hardware package.
3. Position heater base assembly in replace.
4. Place logs in their proper position on heater base.
5. Center heater base and logs front-to-front and side-to-side in replace.
6. Carefully remove logs without moving heater base.
7. Mark screw locations through holes in mounting brackets (see Figure 11). If install
-
ing in a brick-bottom replace, mark screw locations in mortar joint of bricks.
8.
Remove heater base from replace.
9. Drill holes at marked locations using 3/16-inch drill bit.
10. Attach base assembly to replace oor using two masonry screws (in hardware
package) (see Figure 10).

Table of Contents