5
11. Do not run heater where ammable liquids or vapors are used or stored under
dusty conditions.
12
. Turn off heater before using furniture polish, wax, carpet cleaner, or similar products.
13.
Do not use heater if any part has been underwater. Immediately call a qualied
service technician to inspect the room heater and replace any part of the control
system and any gas control which has been underwater.
14.
Turn off and let cool before servicing. Only a qualied service technician should
service and repair heater.
1
5. Operating heater above elevations of 4,500 feet could cause pilot outage.
16. Do not use this heater if any log is broken. Do not operate heater if a log is chipped
(dime-size or larger).
17.
Do not use this heater to cook food or burn paper or other objects.
QUALIFIED INSTALLING AGENCY
Installation and replacement of gas piping, gas utilization equipment or accessories and
repair and servicing of equipment should be performed only by a qualied agency.
The
term “qualied agency” means any individual, rm, corporation, or company that either
in person or through a representative is engaged in and is responsible for:
The installation, testing, or replacements of gas piping or
The connection, installation, testing, repair, or servicing of equipment; that is
experienced in such work; that is familiar with all precautions required; and that has
complied with all the requirement of the authority having jurisdiction.
In areas that prohibit the use of vent-free heaters, the log set has been tested and
approved to the
ANSI Z21.60 standard for Vented Decorative Logs.
a)
b)
PRODUCT FEATURES:
This log set has been tested and approved to ANSI Z21.11.2 standard for Unvented
Heaters and can be operated with the ue damper closed. State and local codes in some
areas prohibit the use of vent-free heaters.
SAFETY PILOT
This heater has a pilot with an Oxygen Depletion Sensing (ODS) safety shutoff system.
The ODS/pilot shuts off the heater if there is not enough fresh air.
THERMOSTAT HEAT CONTROL
The control automatically cycles the burner on and off to maintain a desired room
temperature. See page 25.
PIEZO IGNITION SYSTEM
This heater is equipped with an electronic piezo ignitor. This system requires AAA batter-
ies (provided).
CAUTION: Do not remove the metal data plates from the grate assembly The data
plates contain important product information.
2 FUEL OPTIONS CAPABLE
Your log heater is equipped to operate on either propane or natural gas. The replace
is shipped from the factory ready for connecting to propane. The replace can easily be
changed to natural gas by having your qualied installer follow the instructions on page
18 and the markings on the replace.