English
Operation
The following settings may be changed with Dive.Log or via
"
set 1
"
or
"
set 2
"
directly on
XP10
:
Setting Range Default Page
Maximum partial pressure of oxygen
(ppO
2
max)
Time limit to reset the O
2
% mix to air
Unit system
Audible attention signals
Water contacts
Reset desaturation
Alarm clock
UTC (Universal Time Change) zone
Time of day
24 or AM/PM setting
Date
Display contrast
Sound
1.2-1.6bar
no reset / 1 - 48hrs
metric/imperial
on / off (Dive.Log: selective)
on / off
on / off
0 - 23h 59min, on/off
±13hrs, increments: 15min
hours:minutes
24 (off) / AM/PM (on)
1 (low) -12 (high)
on / off
1.4bar
no reset
on
on
no reset
12:00, off
4
on
32
32
32
33
33
33
34
34
34
35
35
35
35
The following data may be recalled with Dive.Log:
Number of past dives Dive profile
Total duration of dives Logbook
Deepest dive Temperature curve
Longest dive Alarms and attention messages
Atmospheric pressure Battery condition
Downloading your dives
XP10’s memory allows you to store approximately 25 hours of dive profile
information in 4 second sampling intervals. With Dive.Log you can transfer
this information to the PC in order to visualize and analyze your dives on the
monitor. To download data from XP10, click on "NEW" under the
"LOGBOOK" menu to open and name a new logbook or open an existing
logbook. Then click on the "TRANSFER DIVES" icon: a box will appear on
the screen identifying the computer being downloaded, and a progress bar
will show the status of the transfer.
You can choose between transferring all dives or new dives only (default
setting) from XP10’s memory. If you choose to transfer new dives only,
Dive.Log will only transfer dives that are more recent than the most recent dive already saved in the
PC logbook. To transfer all dives, you must change the default setting by selecting "Transfer" under
"Dives" in the main menu bar.
Once the data is downloaded, a window will show you a summary table of all dives; for the selected
dive, another window will show you its details. From these windows you can add and edit your dive
information.