2 Attention messages and alarms
XP10 draws the diver’s attention to certain situations and warns the diver of unsafe diving practices.
Attention messages and alarms are visual and / or audible.
F
• The audible attention messages can be switched off in "set 1" ->33 or Dive.Log. With
Dive.Log they can be switched off selectively.
• In addition, the sound can be turned off completely in "set 2" ->35.
!
WARNING
If you turn off the sound you will have no audible warnings. Without audible warnings you could
inadvertently get into potentially hazardous situations which could result in death or serious injury.
!
WARNING
Serious injury or death may result from failing to immediately respond to alarms given by XP10.
2.1 Attention messages
Attention messages are communicated
to the diver visually by symbols, letters or
flashing figures. In addition, two short audible
sequences can be heard (in an interval of 4
seconds) in two different frequencies under
water.
4s (can be switched off)
Attention messages come up in the following
situations (more information can be found on
the listed pages):
Page
• Maximum Operating Depth /
ppO
2
max is reached 23
• Oxygen toxicity reaches 75% 23
• No-stop time less than 3 minutes 24
• Prohibited altitude (surface mode) 28
• Entering decompression 25
2.2 Alarms
Alarms are given to the diver visually by
flashing symbols, letters or figures. In addition,
an audible sequence in one frequency can be
heard during the whole duration of the alarm.
An alarm occurs in the following situations
(more information can be found on the listed
pages):
Page
• Oxygen toxicity reaches 100% 23
• Ignored decompression 25
• Exceeding the prescribed ascent rate 22
(Particular scale of beeps, ->22)
• Low battery alarm (without audible alarm):
the battery icon appears if the battery
has to be replaced. 15