EasyManua.ls Logo

Sullair SXT - Technical Data; Filter Performance Data

Sullair SXT
52 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
COALESCING FILTERS User Manual | US-EN
23
02250247-389 R02
Subject to EAR. EAR99 and related export control restrictions.
5. Technical data
5.1 Filter performance data
Coalescence lter
0025 0030 0050 0080 0100 0125 0160 0200 0250
Connection [inches] 3/8 1/2 1/2 1/2 3/4 1 1 1 1 1/2
Volume ow rate at 101.53 psi(g)
performance-optimized [scfm]
*1
25 30 50 80 100 125 160 200 250
Dierential
pressure [psi]
(saturated)
CS
Av. 0.94
F 1.45 1.96 2.32 3.48 1.89 2.76 2.76 3.48 1.67
H 1.67 2.32 2.47 3.91 2.25 3.19 3.05 3.99 1.96
Min./max. operating
pressure[psi(g)]
22 ... 232
Min./max.
Operating temperature [°F]
+35 ... +140
Load test in accordance with
AD2000
10000 load changes pressure differential ≥46.41 psi at 232 psi(g)
CRN Canadian Registration No. 0E07304.2C
Weight [lb] 1.65 1.65 1.87 2.65 3.75 3.75 4.63 4.85 9.04
Volume [gal] 0.066 0.066 0.082 0.111 0.230 0.230 0.296 0.333 0.666
*1
Volume ow rate at 101.53 psi(g) based on +68 °F and 14.5 psi(a)