14. Troubleshooting and repair / FAQ
Symptom(s) Possible causes Remedy
Poor compressed quality
Load too high, intermittent load
Change operating method
Avoid pressure surges
Comply with the specied
operating parameters, in
particular during start-up
Non-functional condensate drain
Ensure regular condensate
drainage
Incorrectly dimensioned unit
Dimension lter with indicated
operating parameters and
exchange if necessary
Filter element installed incorrectly
Observe the direction of ow /
installation direction for the lter
element
O-ring was damaged during
installation
Purchase new lter element and
o-ring, install carefully
High pressure dierential
Incorrectly dimensioned unit
Dimension lter with indicated
operating parameters and
exchange for a larger one if
necessary
High level of contamination
Shorten maintenance interval for
exchanging the lter element,
Stepped ltration may be
necessary
Destroyed lter elements
Change operating method
Stepped ltration may be
necessary
Condensate in downstream
components
Condensate drain defective or
functional fault
Exchange oat drain or complete
maintenance on SULLIMAX
Cooling downstream of ltration
section
Drying required before ltration
Leaks
Aging of seals
Replace seals during maintenance
work
Mechanical damage
Send in lter for repairs or
replace with a new one