COALESCING FILTERS User Manual | US-EN
51
02250247-389 R02
Subject to EAR. EAR99 and related export control restrictions.
14. Troubleshooting and repair / FAQ
Symptom(s) Possible causes Remedy
Poor compressed quality
Load too high, intermittent load
• Change operating method
• Avoid pressure surges
• Comply with the specied
operating parameters, in
particular during start-up
Non-functional condensate drain
• Ensure regular condensate
drainage
Incorrectly dimensioned unit
• Dimension lter with indicated
operating parameters and
exchange if necessary
Filter element installed incorrectly
• Observe the direction of ow /
installation direction for the lter
element
O-ring was damaged during
installation
• Purchase new lter element and
o-ring, install carefully
High pressure dierential
Incorrectly dimensioned unit
• Dimension lter with indicated
operating parameters and
exchange for a larger one if
necessary
High level of contamination
• Shorten maintenance interval for
exchanging the lter element,
• Stepped ltration may be
necessary
Destroyed lter elements
• Change operating method
• Stepped ltration may be
necessary
Condensate in downstream
components
Condensate drain defective or
functional fault
• Exchange oat drain or complete
maintenance on SULLIMAX™
Cooling downstream of ltration
section
• Drying required before ltration
Leaks
Aging of seals
• Replace seals during maintenance
work
Mechanical damage
• Send in lter for repairs or
replace with a new one