User Manual | US-EN COALESCING FILTERS
42
02250247-389 R02
Subject to EAR. EAR99 and related export control restrictions.
10. Shutting down
Picture Description
1 3 2
1. Open the shut-o valve [3] of the bypass
line (if available)
2. Close the shut-o valve [2] on the outlet
side
3. Close the shut-o valve [1] on the inlet
side
Picture
Description
Automatic drain Mechanically open
4. Turn the knurled-head screw on the
oat drain from >>automatic drainage<<
counterclockwise (left) to >>mechanically
open<< or press the SULLIMAXTEST
button until the lter is depressurized