User Manual | US-EN COALESCING FILTERS
30
02250247-389 R02
Subject to EAR. EAR99 and related export control restrictions.
The direction of ow for the lter must be observed during installation. This must match the direction of ow for the
pipeline.
Direction of ow
left » right (factory default)
Direction of ow
Right » left
1
2
3
2
1
3
The housing head and housing body use a double trapezoidal thread. The direction of ow through the lter can be
adjusted to that of the pipeline by turning the housing head 180°. The direction of ow is indicated via arrows [2] and
a raised marking [3] on the housing head. This must be aligned as shown. The safety runner [1] must always be easily
accessible on the front side.
For maintenance and repair work, it is recommended to install a bypass line [4] and shut-o valve [5].
4 5
1. Attach sealing material, e.g. PTFE band (EN 837-2) to the pipe ends
2. Screw pipe thread into the lter inlet until the connection is solid and sealed
3. Screw pipe thread into the lter outlet until the connection is solid and sealed
After completing assembly work, check to ensure the housing body is screwed in correctly, the safety runner is pushed
up and the locking screw is hand-tightened. Complete a leak test to check installation work. For more information, see
“9.6 Leak test” on page 41.