TS20C USER MANUAL SECTION 6
112
6.6 FLUID FILTER
MAINTENANCE
Refer to Figure 6-1 & Figure 6-2. Replace the fluid
filter element under any of the following conditions, or
whichever occurs first:
1. Every 2000 hours.
2. When the Supervisor™ panel indicates high
differential pressure.
3. Every fluid change.
FLUID FILTER ELEMENT REPLACEMENT
Refer to Figure 6-1 and Figure 6-2.
1. Use a wrench to remove the filter canister.
2. Remove and dispose of filter element properly.
3. Clean gasket seating surface.
4. Apply a light film of fluid to the element seal.
5. Install the element into the filter canister.
6. Thread the canister and element back on the
filter head.
7. Restart compressor and check for leaks.
Figure 6-1: Fluid Filter Assembly,
100-150
(I) Repair Kit P/N 250025-526
NOTE
Dispose of fluids in accordance with
applicable federal, state and local regula-
tions.
Figure 6-2: Fluid Filter Assembly,
200-250
1. Filter Head
2. Element (I)
3. O-ring Seals (I)
4. Bowl
5. Drain Plug w/O-ring (I)
(I) Element Replacement Kit P/N 02250139-995

Related product manuals