showlogs(8)
392 SPARC Enterprise Mx000 Servers XSCF Reference Manual • Last Revised September 2008
â–  Power log
Date Event Cause DID Switch
Mar 30 17:25:31 JST 2005 System Power Off Power Failure -- Service
Mar 30 17:35:31 JST 2005 System Power On AC Restored -- Locked
Mar 30 17:45:31 JST 2005 Domain Power On Panel 00 Locked
Mar 30 17:50:31 JST 2005 Domain Power Off Operator 10 Service
:
:
Date: Log collection date and time (month day hour:minute:second
time-zone year)
The displayed time is the local time.
Event: Power status
One of the following states is displayed:
Domain Power On The domain power is on.
Domain Power Off The domain power is off.
System Power On The system power is on.
System Power Off The system power is off.
SCF Reset XSCF is in the reset state.
Domain Reset The domain is in the reset state.
XIR The domain CPU is in the reset
state.