ioxadm(8)
System Administration 85
EXAMPLES EXAMPLE 1 Displaying Temperature, Voltage, Current, and Fanspeed Sensor Readings
The External I/O Expansion Unit (box_id) is identified by serial number.
Use iox@nnnn, where nnnn represents the last four digits of the box serial
number.
Some commands affect only a single component of an External I/O
Expansion Unit system. For example, individual boats and power supplies
may be turned on and turned off independently.
An FRU in an External I/O Expansion Unit (fru) is identified as:
iox@nnnn/iob0 I/O boat in the left tray (rear view)
iox@nnnn/iob1 I/O boat in the right tray (rear view)
iox@nnnn/iob0/link Uplink card in boat 0
iox@nnnn/iob1/link Uplink card in boat 1
iox@nnnn/ps0 Power supply in the left bay (front view)
iox@nnnn/ps1 Power supply in the right bay (front view)
XSCF> ioxadm env -te iox@A3B5
Location Sensor Value Res Units
IOX@A3B5/PS0 T_AMBIENT 28.000 1.000 C
IOX@A3B5/PS0 T_CHIP 28.000 1.000 C
IOX@A3B5/PS0 T_HOTSPOT 31.000 1.000 C
IOX@A3B5/PS0 SWITCH On - SWITCH
IOX@A3B5/PS0 V_12V_ANODE 11.703 0.059 V
IOX@A3B5/PS0 V_12V_CATHODE 11.703 0.059 V
IOX@A3B5/PS0 V_ISHARE 0.632 0.040 V
IOX@A3B5/PS0 I_DC 2.316 0.289 A
IOX@A3B5/PS0 S_FAN_ACTUAL 3708.791 40.313 RPM
IOX@A3B5/PS0 S_FAN_SET 4500.000 300.000 RPM
IOX@A3B5/PS1 T_AMBIENT 28.000 1.000 C
IOX@A3B5/PS1 T_CHIP 29.000 1.000 C
IOX@A3B5/PS1 T_HOTSPOT 31.000 1.000 C
IOX@A3B5/PS1 SWITCH On - SWITCH
IOX@A3B5/PS1 V_12V_ANODE 11.762 0.059 V
IOX@A3B5/PS1 V_12V_CATHODE 11.762 0.059 V
IOX@A3B5/PS1 V_ISHARE 0.672 0.040 V