SINGLE PHASE HI 3.6/5kW | User Manual52
What you can do from this page:
Set a real time to start and stop charging or discharging the battery.
Choose to charge the battery from the grid or generator.
Limit export power to the grid.
Set the unit to charge the battery from the grid or generator ticking ‘Grid’ or ‘Gen’ and set what times this
needs to occur.
Set the time to discharge the unit to the load or export to the grid by unticking ‘Grid’ and ‘Gen’.
Zero Export + Limit To Load Only: The hybrid inverter will only provide power to the backup load connect-
ed. The hybrid inverter will neither provide power to the home load nor sell power to the grid. The built-in CT
will detect power owing back to the grid and will reduce the power of the inverter only to supply the local
load and charge the battery.
ZeroExport: The hybrid inverter will not only provide power to the backup load connected but also give
power to the home load connected. If PV power and battery power are insucient, it will take grid energy
as a supplement. The hybrid inverter will not sell power to the grid. In this mode, a CT is needed. For the
installation method of the CT, please refer to the chapter "CT Connection". The external CT will detect power
owing back to the grid and will reduce the power of the inverter only to supply the local load, charge the
battery, and home load.
GridBackup Load On-Grid Home Load
Battery
Solar
GridBackup Load On-Grid Home Load
Battery
Solar
CT