Page | 15
Without a remote temperature sensor, lead-acid batteries may undercharge or overcharge
depending on the ambient temperature of the installation environment. This may result in
a fire hazard.
Depending on the battery type, the inverter should be capable of controlling the
batteries BMS. Therefore, you need to set the protocol of the BMS on both the battery
and the inverter.
When using more than one battery, the first battery will be the master, and the other
batteries will be the slaves. Please, check the battery manufacturer specification for
proper operation.
To verify if the battery is actually communicating access the Li BMS menu as detailed
in section ‘Setting Up a Lithium Battery’ and check whether the values are realistic or
not. It is important that the charge and discharge limits in that page match the numbers
expected for the number of batteries physically connected.
NOTICE