11
Chapter 1: Introduction
Control Panel Features
Feature Description
UID Button
BMC Reset
LED and a blue LED on the rear of the chassis.
This button can also be used to reset the BMC and will disable the rear VGA port to enable
the front VGA port, if available.
Power button
Applies or removes primary power from the power supply to the server but standby power is
maintained
Information LED Alerts operator to several states, as noted in the table below.
NIC LEDs
AIOM
HDD LED
Power LED
Steady on – Power on
Blinking at 4Hz – Checking BIOS/BMC integrity
Blinking at 1Hz and "i" LED red – Fault detected
USB Ports Two USB ports
Information LED
Color, Status Description
Red, solid An overheat condition has occurred.
Red, blinking at 1Hz Fan failure, check for an inoperative fan.
Red, blinking at 0.25Hz
Power failure, check for a non-operational power
supply.
Control Panel
Figure 1-2. Control Panel
UID Button
BMC Reset
Power Button
Power LED
Information LED
HDD LED
NIC LEDs
USB Ports