Chapter 1: Introduction
1.2 System Features
The following views of the system display the main features. Refer to Appendix B for additional

Front View
Figure 1-1. Front View
Logical Storage Drive Numbers
Item Description
0-9 Ten 2.5-inch front drive bays (SAS*/SATA/NVMe*)
* SAS and NVMe support available with additional parts; see optional parts list
Drive Carrier Indicators
Each drive carrier has two LED indicators: an activity indicator and a status indicator. For
        
             
supported, such as hot spare.
Drive Carrier LED Indicators
Color Blinking Pattern Behavior for Device
Activity
LED
Blue Solid On Idle SAS/NVMe drive installed
Blue Blinking I/O activity
󰀨 Idle SATA drive installed
Status
LED
Red Solid On Drive failure
Red Blinking at 1 Hz Rebuilding drive
Red Blinking with two blinks
and one stop at 1 Hz
Hot spare for drive
Red 
󰀨
Power on for drive
Red Blinking at 4 Hz Identifying drive
Green Solid on Safe to remove NVMe drive
Amber Blinking at 1Hz Do not remove NVMe drive
Control Panel