A+ Server AS -4124GS-TNR User's Manual
Reset Button
The Reset Button connection is located on pins 3 and 4 of JF1. Attach it to a hardware reset
Reset Button
Pin Denitions (JF1)
Pins Denition
3 Reset
4 Ground
Power Fail LED
The Power Fail LED connection is located on pins 5 and 6 of JF1.
Power Fail LED
Pin Denitions (JF1)
Pin# Denition
5 Power Fail LED+
6 Power Fail LED-
Power Fail LED
Status
LED State Status
Solid on Overheat
Fast Blinking Fan Fail
Slow Blinking Power Fail
Unit Identier Switch/UID LED Indicator
located on the serverboard. The rear UID LED is located next to the UID switch. The front
UID LED is located on pins 7 & 8 on the front control panel (JF1). When you press the UID
switch, both rear and front UID LED indicators will be turned on. Press the UID switch again
that may be in need of service.
Note: UID can also be triggered via IPMI on the serverboard. For more information on IPMI,
please refer to the IPMI User's Guide posted on our website at http://www.supermicro.com.