SC826 Chassis Manual
3-4
Responses
If the server overheats
1. Use the LEDs to determine the nature of the overheating condition.
2. Conrm that the chassis covers are installed properly.
3. Check the routing of the cables and make sure all fans are present and operating
normally.
4. Verify that the heatsinks are installed properly.
3-4 Drive Carrier LEDs
The chassis includes externally accessable SAS/SATA drives. Each drive carrier
displays two status LEDs on the front of the carrier.
Green: When illuminated, this LED indicates drive activity. It blinks on and off
when that particular drive is being accessed This function is controlled by the
backplane.
Red: When illuminated, this LED indicates a drive failure. You should be notied
by your system management software.
3-5 Power Supply LEDs
On the rear of the power supply module, an LED displays the status.
Solid Green: When illuminated, indicates that the power supply is on.
Solid Amber: When illuminated, indicates the power supply is plugged in and
turned off, or the system is off but in an abnormal state.
Blinking Amber: When blinking, this system power supply temperature has
reached 63°C. The system will automatically power-down when the power supply
temperature reaches 70°C and restarts when the power supply temperature
goes below 60°C.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Supermicro SC826BE1C-R920LPB and is the answer not in the manual?

Supermicro SC826BE1C-R920LPB Specifications

General IconGeneral
BrandSupermicro
ModelSC826BE1C-R920LPB
CategoryChassis
LanguageEnglish

Related product manuals