Appendix F CPU-Based RAID for NVMe
141
Figure F-3. Created Volume without
enabling RAID spanned over VMD
controller
Figure F-4. Created Volume with
enabling RAID spanned over VMD
controller
11. If cross-controller RAID is required, select Enable RAID spanned over VMD
Controller as shown in Figure F-4.
12. 

RAID1: Select only two disks

RAID10: Select only four disks
13. Select Strip Size (Default 64KB).
14. Select Create Volume.
15. If another RAID is needed, start again at step 6.