Chapter 7: BIOS
7-31
When SEL is Full
This feature allows the user to decide what the BIOS should do when the system
event log is full. Select Erase Immediately to erase all events in the log when the
system event log is full. The options are Do Nothing and Erase Immediately.
Note: After making changes on a setting, be sure to reboot the system for
the changes to take effect.
BMC Network Conguration
BMC Network Conguration
IPMI LAN Selection
This item displays the IPMI LAN setting. The default setting is Failover.
IPMI Network Link Status
This item displays the IPMI Network Link status. The default setting is Shared LAN.
Update IPMI LAN Conguration
Select Yes for the BIOS to implement all IP/MAC address changes at the next
system boot. The options are No and Yes
Conguration Address Source (Available for conguration if "Update IPMI
LAN Conguration" is set to Yes)
This feature allows the user to select the source of the IP address for this com-
puter. If Static is selected, you will need to know the IP address of this computer

      
that is attached to and request the next available IP address for this computer.
The options are DHCP and Static. The following items are assigned IP addresses
automatically if DHCP is selected.
Station IP Address
This item displays the Station IP address for this computer. This should be in decimal
and in dotted quad form (i.e., 192.168.10.253).
Subnet Mask
This item displays the sub-network that this computer belongs to. The value of each
three-digit number separated by dots should not exceed 255.
Station MAC Address
This item displays the Station MAC address for this computer. Mac addresses are
6 two-digit hexadecimal numbers.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Supermicro SUPERSERVER 5018D-MHR7N4P and is the answer not in the manual?

Supermicro SUPERSERVER 5018D-MHR7N4P Specifications

General IconGeneral
BrandSupermicro
ModelSUPERSERVER 5018D-MHR7N4P
CategoryServer
LanguageEnglish

Related product manuals