Hex 1B 5C nL nH
Decimal 27 92 nL nH
[Range] 0 ≤ nL ≤ 255
0 ≤ nH ≤ 255
[Description] On basis of present position, set print starting position by horizontal and
vertical motor unit.
· This command set the print position from present position to [(nL + nH
×
256)
× 0.125 mm] 。
[Notes] · Any set over printable area which will be ignored.
· Spacing N points the right:
nL + nH ´ 256 = N
Spacing
N point the left
: (negative direction ), uses 65536 complement code.
nL + nH ´ 256 = 65536 - N
· In stable mode, uses horizontal motor unit.
[Reference] ESC
ESC
ESC
ESC $
$
$
$
ESC
ESC
ESC
ESC c
c
c
c 3
3
3
3 n
n
n
n
[Name] Select paper sensors to output paper-end signals
[Format] ASCII ESC c 3 n
Hex 1B 63 33 n
Decimal 27 99 51 n
[Range] 0 ≤ n ≤ 255
[Description] Select paper sensors to output paper-end signals.
· Uses each parameter n as follows:
Bit Off/On Hex Decimal Function
0 Off - - Undefined.
1 Off 00 0
Roll paper near-end
sensor disable.
On 02 2
Roll paper near-end
sensor enable.
2 Off - - Undefined.
3 Off 00 0
Roll paper end sensor
disable.
On 08 8
Roll paer end sensor
enable.
4-7 - - - Undefind.
[Notes] · Select several sensors and input signal. In this case, if any one of sensors detect
paper out, it will output paper out signal.
· This command only effects to parallel interface, in serial interface mode, this
command will be ignored.
[Default] n = 0
ESC
ESC
ESC
ESC c
c
c
c 4
4
4
4 n
n
n
n
[Name] Select paper sensors to stop printing