EasyManua.ls Logo

Sutter Instrument P-97 - Page 9

Sutter Instrument P-97
66 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
vii
4.2.3 Positioning the Filament in Relation to the Glass Capillary ..............................................33
4.3 Pulley Adjustment ..........................................................................................................................35
4.4 Regeneration of Drierite Granules................................................................................................36
4.4.1 Removing the Canister ............................................................................................................36
4.4.2 Replacing the Granules ...........................................................................................................36
4.4.3 Reinstalling the Canister.........................................................................................................37
5. TROUBLESHOOTING ....................................................................................................................39
5.1 Controlling Pipette Tip Shapes .....................................................................................................39
5.1.1 Problem: What type of glass should be used? .......................................................................39
5.1.2 Problem: The resistance of pulled pipettes is too low. How can a higher-resistance
pipette be pulled?...............................................................................................................................39
5.1.3 Problem: Okay, but how can tips be made even smaller. ....................................................39
5.1.4 Problem: How can the size of a patch-pipette be increased?...............................................40
5.1.5 Problem: Patch-pipette tips vary in size from pull to pull...................................................40
5.1.6 Problem: Difficulty making an injection pipette with a 0.5 – 1 mm tip that also has a
very short final taper and tip (20 to 50 mm long). How can this be done? .................................40
5.1.7 Problem: The electrodes are bent. How can they be made to pull straight? .....................40
5.1.8 Problem: One electrode is much longer than the other electrode. .....................................40
5.1.9 Problem: The shape and resistance of the pipette changes from pull to pull....................41
5.2 Controller problems........................................................................................................................41
5.2.1 Problem: The filament does not light up when pull is pressed...........................................41
5.2.2 Problem: Display blank, fan not on, or locked up/overlap...................................................42
5.2.3 Problem: Display only shows a cursor. ..................................................................................42
5.2.4 Problem: Displayed program values are not correct ............................................................42
5.3 Technical Support...........................................................................................................................42
APPENDIX A. Limited Warranty........................................................................................................43
APPENDIX B. Accessories....................................................................................................................45
Filaments ...............................................................................................................................................45
Capillary Glass Tubing.........................................................................................................................45
Other Accessories..................................................................................................................................45
APPENDIX C. Fuse Replacement........................................................................................................47
APPENDIX D. Technical Specifications..............................................................................................49
APPENDIX E. Drierite Material Safety Data Sheet ..........................................................................51
INDEX ....................................................................................................................................................53
TABLE OF FIGURES
Figure 1-1. P-97 Front panel. .................................................................................................................... 2
Figure 1-2. Program Display. .................................................................................................................... 3
Figure 1-3. P-97 base plate (top view, cover removed). ..........................................................................5
Figure 1-4. Filament Block Assembly. ..................................................................................................... 6
Figure 1-5. Upper cable pulley assembly. ................................................................................................ 7
Figure 2-1. P-97 Cabinet (rear view), showing power entry module. ................................................. 10
P-97 FLAMING/BROWN MICROPIPETTE PULLER OPERATION MANUAL – REV. 2.43 - DOM (20161118)

Table of Contents

Related product manuals