3·11
ENGINE
Connect
all
the
cables
to
the
actuator pulley @ properly.
Cable
CD
identification marking: (12C-l)
· Cable
@ identification marking: (12C-2)
Cable
@ identification marking: (12C-3)
Cable
@ identification marking: (12C·4)
Mount
the
pulley @ on
the
actuator.
Tightening
torque:
4 - 6 N·m (0.4 -
0.6
kg·m)
Install
the
actuator
assembly ®
to
the
electric parts holder.
With
the
actuator mounted, install
the
electric part holder
(j) on
the
frame.
I nstall
the
thermostat case
®.
Assemble
the
throttle cable pulleys.
Throttle
cable pulley ®
·
Oil
pump
pulley ®
Actuator
pulley
(j])
· Spring @
Insert
the
pulley shaft
in
position.
Connect
the
cables.
Throttle
cable No. 1: @
·
Throttle
cable No. 2: @
Throttle cable No. 3: @
Actuator cable @
Oil
pump cable @
Cover
the
junction box properly with its cap.