EN
40
Par. Indication Description Value range, Unit Factory Change/
No. in display physical value setting Display
V/Hz characteristic (ASM motor)
P60 U0 Start-up voltage at f=0 3% U_nom, 1...50 V~ 3% U_nom I M
P61 f1 1st characteristic point frequency f_nom, 30...4000 Hz f_nom I M
P62 U1 1st characteristic point voltage U_nom , 1...50 V~ U_nom I M
P63 f2 2nd characteristic point frequency f_nom, 30...4000 Hz f_nom I M
P64 U2 2nd characteristic point voltage U_nom, 1...50 V~ U_nom I M
P65 f3 3rd characteristic point frequency f_nom, 30...4000 Hz f_nom I M
P66 U3 3rd characteristic point voltage U_nom, 1...50 V~ U_nom I M
Control
P70 control Control principle speed control V/Hz, I*R - V/Hz-Tab. I M
P71 I*R-factor I*R compensation gain factor Off, 0, 1...10 V/A off I M *
P72 loadcomp. Load compensation gain factor of, 0.1...40 %/A~ off I M *
P73 komp-t_filt I*R and load compensation. Filter time 1...1000 ms 20 I M *
P77 I-limtr-KP Current limitation P-component 2...200 % 40 I
P78 I-limtr-t_n Current limitation I-component reset time 1...999, without I-part ms 2 I
P79 V-contr-KP Voltage control V_WR P-component 5...100 % 20 I
P80 V-contr-t_n Voltage control I-component reset time 5...999, without I-part ms 2 I
P81 N-contr-KP Speed control P-component 5...500 % 50 I
P82 N-contr-t_n Speed control I-component reset time 5...999 ms 250 I
P83 N-contr-t_v Speed control D-component 1...300 ms 30 I
P84 N-contr-t_fil Speed control filter D-component 1...300 ms 200 I
Monitoring
P85 motor protection Monitoring motor temperature Off, PTC, KTY - PTC I
P86 R_protect Resistance value for sensor KTY 500...4000 W 1200 I *
Rated motor data (according to rating plate)
P90 motortype Motor design No, ASM, BLDC, BLDCS - no motor S
P91 f_mot_nom Rated motor frequency 30...4000 Hz 100 S
P92 V_mot_nom Rated motor voltage 0...50 V~ 6 S
P93 I_mot_nom Rated motor current 0.5...16 A~ 1.0 S
P94 cos_phi Cosine phi at nominal load 20...100 % 85 S
P96 no. of poles Number of poles 2, 4, 6, 8 - 2 S
Device parameters /
Ext. brake resistance
P102 motor coding Motor coding, number of motors Off, 2...32 motors - off S
Fixed frequency
P104 FF1 Fixed frequency FF1 (select with IN3,IN4) 30...4000 Hz 100 I
P105 FF2 Fixed frequency FF2 30...4000 Hz 100 I
P106 FF3 Fixed frequency FF3 30...4000 Hz 100 I
Remote Control
P110 input IN1 Function digital input IN1 Off, start/stop, stop - off S
P111 input IN2 Function digital input IN2 Off, Start pulse, reset, left, motor code off S
P112 input IN3 Function digital input IN3 Off, reset, left, motor code - off S
P113 input IN4 Function digital input IN4 Off, reset, left, motor code - off S
P114 input IN5 Function digital input IN5 Off, reset, left, motor code, FF - off S
P115 input IN6 Function digital input IN6 Off, reset, left, motor code, FF - off S
P120 relay REL1 Function relay output REL1 Off, various status signals - f_rated I
P121 relay REL2 Function relay output REL2 Off, various status signals - overload I
P125 I_warning Var. current limit for relay output 0.4...12 A~ 0.4 I
P129 choose analog AIN Source for analogue input AIN1 U(0...10 V), I(0...20 mA) - V(0...10 V) S
P135 f_rem_min Min. rated freq. of analogue input 0...4000 Hz 30 I
P136 f_rem_max Max. rated freq. of analogue input 0...4000 Hz 4000 I
P137 f_stop_analog Stop via analogue signal Off,1...4000 Hz Aus I
P140 input for start Input motor start PC, remote control - AIN1 I
P141 input for f_sollInput frequency setpoint PC, AIN - AIN1 I
P142 enabling FF Release fixed frequency stopped, on - stopped I
P146 direction of rotation Direction of rotation right, left, remote control - right hand I
P150 End End mark- -