P80 V-contr-t_n [ASM, BLDC, BLDCS]
Only in special cases should this parameter be changed from the factory setting.
P80-V-contr-t_n influences the control (PI) for the internal intermediate circuit voltage, it being possible
to set the reset time (integral part) here. Longer times make the control slower.
Specific values: Without I-part - I-part is switched off
Minimum value: 1 ms
Maximum value: 1,000 ms
Factory setting: 2 ms
P81 N-contr-KP [ASM, BLDC, BLDCS]
This parameter influences the control (PID) for the motor speed (proportional part).
Minimum value: 5%
Maximum value: 500%
Factory setting: 50%
P82 N-contr-t_n [ASM, BLDC, BLDCS]
This parameter influences the control (PID) for the motor speed, it being possible to set the reset time
(integral part) here. Shorter times make the control faster and longer times make it slower.
Specific values: Without I-part - I-part is switched off
Minimum value: 5 ms
Maximum value: 999 ms
Factory setting: 200 ms
P83 N-contr-t_v [ASM, BLDC, BLDCS]
This parameter influences the control (PID) for the motor speed, it being possible to set the derivative
time (D-part) here. Longer times make the control faster and shorter times make it slower.
Specific values: Without D-part - D-part switched off
Minimum value: 1 ms
Maximum value: 300 ms
Factory setting: 8 ms
P84 N-contr-t_fil [ASM, BLDC, BLDCS]
This parameter influences the control (PID) for the motor speed, it being possible to set the filter before
the D-part here. The filter makes the D-part smoother and slightly slower. In the case of longer times,
the tendency of the D-part to oscillate is damped.
Minimum value: 1 ms
Maximum value: 300 ms
Factory setting: 50 ms
8.13 Monitoring
P85 motor protection [ASM, BLDC, BLDCS]
The temperature of the motor can be monitored with various sensors, and the sensor type should be set
here.
Values: no sensor
- There is no temperature monitoring of the motors
PTC
- Positive temperature coefficient sensor (according to DIN 44081) with fixed
switching thresh olds, the cut-out temperature is determined by the sensor itself.
KTY
- Analogue semiconductor sensor, the switching threshold can be set with P86-
R_protect
Factory setting: no sensor