P15 V_motor (display value)
V_motor is the current motor voltage between two phases.
P16 V_DC_link (display value)
V_DC_link is the current intermediate circuit voltage.
P18 I_mot (display value)
I_mot is the current real motor current in a phase.
P19 P_real (display value)
P_real is the current inverter output power, corresponding to the real power consumed by the motor.
P20 motor code (display value)
The currently used motor parameter memory M1...M32 is displayed. f the parameters from the memory
have been changed, the display of the memory is not present.
P25 inverter (display value)
inverter shows the total operating hours of the device in hours.
The value is read in from the EEPROM.
P26 motor (display value)
motor shows the operating hours of the motor.
The value is read in from the EEPROM.
P30 1st error (display value)
1st error shows the error number of the last error which occurred.
The value is read in from the EEPROM.
P31 2nd error (display value)
2nd error shows the error number of the penultimate error which occurred.
The value is read in from the EEPROM.
P32 3rd error (display value)
3rd error shows the error number of the third-last error which occurred.
The value is read in from the EEPROM.
P33 4th error (display value)
4th error shows the error number of the fourth-last error which occurred.
The value is read in from the EEPROM.
P34 5th error (display value)
5th error shows the error number of the fifth-last error which occurred.
The value is read in from the EEPROM.
P36 Inverter (display value)
Inverter shows the frequency inverter type (e.g. e@syDrive "4425").
P37 SW panel (display value)
SW panel shows the version and the date of the operating firmware.
P39 Serialno. (display value)