Do you have a question about the Symbol CS4070 and is the answer not in the manual?
Guide provides setup, operation, maintenance, and troubleshooting instructions for the scanner.
Scanner available in CS4070SR and CS4070HC configurations, includes micro USB cable.
Refers to Table B-1 for a list of available accessories.
Scanner captures, stores, and transmits bar codes via USB or Bluetooth.
Remove protective material, save packaging, verify contents, contact support for missing/damaged items.
Insert battery bottom-first into compartment and press down until latch snaps.
Pull release latch, pull back on indent, battery rotates and pops up for removal.
Charge battery via micro USB cable to host or power adapter, or use charging cradle.
Insert spare battery into charging accessory slot with contacts facing down.
Charge batteries within temperature range 0°C to 35°C.
Micro USB cable enables PC communication and battery charging.
Options for connecting via Bluetooth Serial Port Profile or Human Interface Device Emulation.
Supports iOS, Android, Windows 8 Pro, Windows 7 Pro, Windows XP, Windows RT, and Windows Embedded Compact devices.
Use 123Scan2 utility to generate and scan 2D bar codes for configuration.
Configure by scanning parameter bar codes from Chapters 3 and 4, or edit Config.ini file.
Copy config.ini from a master scanner to clone settings onto multiple scanners via USB.
Connect via USB, copy .dat and .bin files to scanner root directory to update firmware.
Instructions for scanning bar codes, sending data, and definitions for beeper and LED indicators.
Aim scanner at bar code and press scan button to scan.
Scanned data is stored in BarcodeFile.txt in \Scanned Barcodes directory.
Data transmits directly to host via Bluetooth after each scan, not stored on device.
Table 2-1 details LED feedback for various scanner functions and events.
Describes user preference features and provides programming bar codes for selection.
Scan one bar code to set parameter values; examples for beeper tone.
Rescan correct parameter to fix errors during scanning sequences.
Scan "Set Date" bar code, then six digits in mmddyy format.
Scan "Set Time" bar code, then four digits in hhmm format.
Scan "Cancel Set Date/Time" bar code to cancel settings.
Scanner can be master or slave; slave mode is discoverable and connectable.
Create pairing bar code for master connection to remote Bluetooth device.
Enable or disable decoding of parameter bar codes for scanner configuration.
Select whether the scanner beeps after a successful bar code decode.
Select Symbol Code ID, AIM Code ID, or None to identify scanned bar code type.
Scan bar code to transmit firmware version to the host.
Scan bar code to transmit scan engine version to the host.
Scan bar code to transmit dongle version to the host.
Describes symbology features and provides programming bar codes for scanner selection.
Scan one bar code to set parameter values; examples for check digit transmission.
Scan bar code to enable or disable UPC-A symbology.
Scan bar code to enable or disable UPC-E symbology.
Scan bar code to enable or disable Code 128 symbology.
Set lengths for Code 128 using one discrete, two discrete, range, or any length options.
Scan bar code to enable or disable Code 39 symbology.
Scan bar code to enable or disable Trioptic Code 39 variant.
Scan bar code to enable or disable Code 93 symbology.
Set lengths for Code 93 using one discrete, two discrete, range, or any length options.
Scan bar code to enable or disable Code 11 symbology.
Set lengths for Code 11 using one discrete, two discrete, range, or any length options.
Scan bar code to enable or disable Interleaved 2 of 5 symbology.
Set lengths for Interleaved 2 of 5 using one discrete, two discrete, range, or any length options.
Scan bar code to enable or disable Discrete 2 of 5 symbology.
Set lengths for Discrete 2 of 5 using one discrete, two discrete, range, or any length options.
Scan bar code to enable or disable Codabar symbology.
Set lengths for Codabar using one discrete, two discrete, range, or any length options.
Scan bar code to enable or disable MSI symbology.
Set lengths for MSI using one discrete, two discrete, range, or any length options.
Scan bar code to enable or disable Chinese 2 of 5 symbology.
Scan bar code to enable or disable Matrix 2 of 5 symbology.
Set lengths for Matrix 2 of 5 using one discrete, two discrete, range, or any length options.
Scan bar code to enable or disable Korean 3 of 5 symbology.
Scan bar code to enable or disable GS1 DataBar-14 variant.
Scan bar code to enable or disable GS1 DataBar Limited variant.
Scan bar code to enable or disable Composite CC-C bar codes.
Scan bar code to enable or disable Composite CC-A/B bar codes.
Scan bar code to enable or disable US Postnet postal code.
Scan bar code to enable or disable US Planet postal code.
Scan bar code to enable or disable PDF417 symbology.
Scan bar code to enable or disable MicroPDF417 symbology.
Set decode redundancy level (1-4) based on bar code quality.
123Scan² is PC software for customized scanner setup, firmware upgrades, and bar code generation.
Connect scanner to host computer via USB cable to communicate with 123Scan².
ADF customizes scan data before host transmission using bar code programmed rules.
Provides scanner maintenance, troubleshooting, and technical specifications.
Clean scan window with damp cloth; avoid abrasive materials.
Accessories provide product support including cables, cradles, chargers, mounts, and lanyards.
Table B-2 details LED indications for spare battery charging status.
CS4070 maintains Bluetooth communication when in a charging cradle.
Bracket KT-102376-01R mounts one eight-slot spare battery charger to a wall.
Bracket KT-102375-01R mounts eight-slot CS4070 charger or two spare battery chargers to a wall.
Illustrates how to attach and detach the lanyard from the scanner.
Pairing involves discoverable mode and PIN entry; provides connection examples for iPad, Android, Windows 7/8.
Table D-1 lists SDL Code Type IDs and their corresponding Bar Code Types.
Sample UPC-A barcode for reference.
Sample UPC-E barcode for reference.
Sample UPC-E1 barcode for reference.
Sample EAN-13 barcode for reference.
Sample EAN-8 barcode for reference.
Sample Code 39 barcode for reference.
Sample Trioptic Code 39 barcode for reference.
Sample Code 93 barcode for reference.
Sample Code 11 barcode for reference.
Sample Codabar barcode for reference.
Sample MSI barcode for reference.
Sample Interleaved 2 of 5 barcode for reference.
Sample GS1 DataBar-14 barcode for reference.
Sample PDF417 barcode for reference.
Sample Data Matrix barcode for reference.
Sample Maxicode barcode for reference.
Sample QR Code barcode for reference.
Sample Han Xin barcode for reference.
Sample US Postnet barcode for reference.
Sample UK Postal barcode for reference.
Numeric bar codes (0-9) for entering specific parameter values.
Table lists ASCII values, Code 39 encode chars, and keystrokes.
Guide provides setup, operation, maintenance, and troubleshooting instructions for the scanner.
Scanner available in CS4070SR and CS4070HC configurations, includes micro USB cable.
Refers to Table B-1 for a list of available accessories.
Scanner captures, stores, and transmits bar codes via USB or Bluetooth.
Remove protective material, save packaging, verify contents, contact support for missing/damaged items.
Insert battery bottom-first into compartment and press down until latch snaps.
Pull release latch, pull back on indent, battery rotates and pops up for removal.
Charge battery via micro USB cable to host or power adapter, or use charging cradle.
Insert spare battery into charging accessory slot with contacts facing down.
Charge batteries within temperature range 0°C to 35°C.
Micro USB cable enables PC communication and battery charging.
Options for connecting via Bluetooth Serial Port Profile or Human Interface Device Emulation.
Supports iOS, Android, Windows 8 Pro, Windows 7 Pro, Windows XP, Windows RT, and Windows Embedded Compact devices.
Use 123Scan2 utility to generate and scan 2D bar codes for configuration.
Configure by scanning parameter bar codes from Chapters 3 and 4, or edit Config.ini file.
Copy config.ini from a master scanner to clone settings onto multiple scanners via USB.
Connect via USB, copy .dat and .bin files to scanner root directory to update firmware.
Instructions for scanning bar codes, sending data, and definitions for beeper and LED indicators.
Aim scanner at bar code and press scan button to scan.
Scanned data is stored in BarcodeFile.txt in \Scanned Barcodes directory.
Data transmits directly to host via Bluetooth after each scan, not stored on device.
Table 2-1 details LED feedback for various scanner functions and events.
Describes user preference features and provides programming bar codes for selection.
Scan one bar code to set parameter values; examples for beeper tone.
Rescan correct parameter to fix errors during scanning sequences.
Scan "Set Date" bar code, then six digits in mmddyy format.
Scan "Set Time" bar code, then four digits in hhmm format.
Scan "Cancel Set Date/Time" bar code to cancel settings.
Scanner can be master or slave; slave mode is discoverable and connectable.
Create pairing bar code for master connection to remote Bluetooth device.
Enable or disable decoding of parameter bar codes for scanner configuration.
Select whether the scanner beeps after a successful bar code decode.
Select Symbol Code ID, AIM Code ID, or None to identify scanned bar code type.
Scan bar code to transmit firmware version to the host.
Scan bar code to transmit scan engine version to the host.
Scan bar code to transmit dongle version to the host.
Describes symbology features and provides programming bar codes for scanner selection.
Scan one bar code to set parameter values; examples for check digit transmission.
Scan bar code to enable or disable UPC-A symbology.
Scan bar code to enable or disable UPC-E symbology.
Scan bar code to enable or disable Code 128 symbology.
Set lengths for Code 128 using one discrete, two discrete, range, or any length options.
Scan bar code to enable or disable Code 39 symbology.
Scan bar code to enable or disable Trioptic Code 39 variant.
Scan bar code to enable or disable Code 93 symbology.
Set lengths for Code 93 using one discrete, two discrete, range, or any length options.
Scan bar code to enable or disable Code 11 symbology.
Set lengths for Code 11 using one discrete, two discrete, range, or any length options.
Scan bar code to enable or disable Interleaved 2 of 5 symbology.
Set lengths for Interleaved 2 of 5 using one discrete, two discrete, range, or any length options.
Scan bar code to enable or disable Discrete 2 of 5 symbology.
Set lengths for Discrete 2 of 5 using one discrete, two discrete, range, or any length options.
Scan bar code to enable or disable Codabar symbology.
Set lengths for Codabar using one discrete, two discrete, range, or any length options.
Scan bar code to enable or disable MSI symbology.
Set lengths for MSI using one discrete, two discrete, range, or any length options.
Scan bar code to enable or disable Chinese 2 of 5 symbology.
Scan bar code to enable or disable Matrix 2 of 5 symbology.
Set lengths for Matrix 2 of 5 using one discrete, two discrete, range, or any length options.
Scan bar code to enable or disable Korean 3 of 5 symbology.
Scan bar code to enable or disable GS1 DataBar-14 variant.
Scan bar code to enable or disable GS1 DataBar Limited variant.
Scan bar code to enable or disable Composite CC-C bar codes.
Scan bar code to enable or disable Composite CC-A/B bar codes.
Scan bar code to enable or disable US Postnet postal code.
Scan bar code to enable or disable US Planet postal code.
Scan bar code to enable or disable PDF417 symbology.
Scan bar code to enable or disable MicroPDF417 symbology.
Set decode redundancy level (1-4) based on bar code quality.
123Scan² is PC software for customized scanner setup, firmware upgrades, and bar code generation.
Connect scanner to host computer via USB cable to communicate with 123Scan².
ADF customizes scan data before host transmission using bar code programmed rules.
Provides scanner maintenance, troubleshooting, and technical specifications.
Clean scan window with damp cloth; avoid abrasive materials.
Accessories provide product support including cables, cradles, chargers, mounts, and lanyards.
Table B-2 details LED indications for spare battery charging status.
CS4070 maintains Bluetooth communication when in a charging cradle.
Bracket KT-102376-01R mounts one eight-slot spare battery charger to a wall.
Bracket KT-102375-01R mounts eight-slot CS4070 charger or two spare battery chargers to a wall.
Illustrates how to attach and detach the lanyard from the scanner.
Pairing involves discoverable mode and PIN entry; provides connection examples for iPad, Android, Windows 7/8.
Table D-1 lists SDL Code Type IDs and their corresponding Bar Code Types.
Sample UPC-A barcode for reference.
Sample UPC-E barcode for reference.
Sample UPC-E1 barcode for reference.
Sample EAN-13 barcode for reference.
Sample EAN-8 barcode for reference.
Sample Code 39 barcode for reference.
Sample Trioptic Code 39 barcode for reference.
Sample Code 93 barcode for reference.
Sample Code 11 barcode for reference.
Sample Codabar barcode for reference.
Sample MSI barcode for reference.
Sample Interleaved 2 of 5 barcode for reference.
Sample GS1 DataBar-14 barcode for reference.
Sample PDF417 barcode for reference.
Sample Data Matrix barcode for reference.
Sample Maxicode barcode for reference.
Sample QR Code barcode for reference.
Sample Han Xin barcode for reference.
Sample US Postnet barcode for reference.
Sample UK Postal barcode for reference.
Numeric bar codes (0-9) for entering specific parameter values.
Table lists ASCII values, Code 39 encode chars, and keystrokes.
| Scanner Type | Handheld |
|---|---|
| Connectivity | Bluetooth |
| Battery | Lithium-ion |
| IP Sealing | IP42 |
| Scan Technology | Laser |
| Scan Rate | 100 scans per second |
| Drop Specification | 5 ft./1.52 m drop to concrete |
| Operating Temperature | 0°C to 40° C |
| Bluetooth Class | Class 2 |
| Bluetooth Range | Up to 10 m (33 ft) |
| Operating Time | 12 hours |
| Interface | USB |
| Resolution | 4 mil |
| Light Source | Laser diode |
| Storage Temperature | -40°C to 70°C |
| Humidity | 5% to 95% (non-condensing) |
| Drop Specification (Alternative) | 1.8 m (6 ft) to concrete |
| Electrical Safety | UL |
| Regulatory Compliance | FCC, CE |