This section explains how to make a cascade connection
between two DM-3200s that are running Version 1.20.
1 Using the TASCAM cascade cable (PW-1000CS –
sold separately), connect the CASCADE ports of the
two DM-3200.
Only use the special TASCAM cascade cable. Use of
any other type of cable may result in damage to the
equipment.
2 Set one of the DM-3200 units to be the cascade
master, and the other the cascade slave.
To set the master and slave, display the DIGITAL screen
using the DIGITAL key in the SCREEN MODE/NUMERIC
ENTRY section, and use the POD 3 key (or continue pressing
the DIGITAL key) to display the CASCADE sub-screen. Set
the ID of one of the units to MASTER, and the other to SLAVE.
Figure 13: DIGITAL>CASCADE screen
Set the unit ID while the ON/OFF set-up is OFF. You
cannot change the ID set-up while it is ON.
3 Turn the ON/OFF setting on the CASCADE
sub-screen of the cascade master to ON.
Move the cursor to the ON/OFF button and press the
ENTER key. A confirmation screen will come up. Check
the setting and press the ENTER key again to confirm.
ON/OFF status cannot be changed while the timecode
is running.
4 When a cascade connection is established, a pop-up
message “Cascade connection established” will be
displayed. Press the ENTER key.
If a cascade connection was not properly established,
a pop-up message “Cascade Slave not found. Cascade
connection not established” will be displayed.
Making a cascade connection