Example of menu operation.
P3
CH
01 01
PARAMETER
PARAMETER 01:
CONFIRM
P1
P2
P3
P3
0.1.
0.2.
Premere il pulsante per
un paio di secondi.
Press the button for
few seconds.
PAR.
PARAMETER NAME DESCRIPTION VALUE DE-
FAULT
01 Motor type selec-
tion: 1,5 KW or 0,75
KW
0.1 = 1,5 KW motor (BIG40QI)
0.2 = 0,75 KW motor (BIG25QI)
0.1
0.2
0.1
02 Automation weight
selection
a. = LIGHTWEIGHT door/gate
b. = MEDIUMWEIGHT door/gate
c. = HEAVYWEIGHT door/gate
a.
b.
c.
c.
03 Change STOP time Check the automatic closing time
set during the stroke calibration
procedure. This time can be chan-
ged from 1 to 99 s.
from
0.0. to
9.9. s
-
04 Torque adjustment
max.
Motor force adjustment from
0.1. to
9.9.
9.2.
05 Working speed
adjustment in OPE-
NING
Speed adjustment from
0.4. to
9.9.
5.0
06 Working speed
adjustment in CLO-
SING
Speed adjustment from
0.4. to
9.9.
5.0
07 Deceleration speed
adjustment in OPE-
NING
Adjustment of the deceleration
speed during opening
from
0.4. to
9.9.
2.5
08 Acceleration speed
adjustment in CLO-
SING
Adjustment of the acceleration
speed during closing
from
0.4.. to
9.9.
2.5
09 Force adjustment on
obstacle in OPENING
Adjustment of the impact force on
any obstacle during opening.
(0.0 = sensitivity disabled -
0.1 = maximum sensitivity -
9.9 = minimum sensitivity)
from
0.0. to
9.9.
3.5