33
20 Steady ashing fun-
ction selection
By enabling the function, the
ashing light will output a steady
light, without ashing. (yes = ena-
ble/no = disable)
YES and
NO
NO
21 Re-closing after pho-
tocell intervention
Pay attention to the automatic
reclosing time set after the inter-
vention of the photocells; this value
must always be lower than the
automatic closing time.
from
0.0. to
9.9. s
NO
22 Dead man The gate only works by keeping the
START key pressed to open and the
PEDESTRIAN key to close
(yes = enable/no = disable)
YES and
NO
NO
23 Selection of the sen-
sitive edge on the
pedestrian input
YES = use in pedestrian input to
connect a sensitive edge
No = use of the pedestrian input to
control the pedestrian opening.
YES and
NO
NO
15. MALFUNCTIONS: POSSIBLE CAUSES AND REMEDIES
ERROR ERROR NAME + DESCRIPTION REMEDY
A5 Obstacledetected.
Obstacle detected during the
opening or closing maneuver
Adjust parameters 9-10-11-12.
E0 Microcontroller operation
problem.
The working times of the micro-
controller are not correct
If the problem persists, replace the
control panel.
E1 Both limit switches pressed
simultaneously
The only non-blocking error.
It happens when both limit
switches are pressed at the same
time; a situation that is impossi-
ble to occur during the correct
operation of the automation.
(DL8 and DL9 o)
Check the operation of the limit
switches (N.C.).
E2 Short circuit of the motor Check that the motor1 phases are
not short-circuited and that the
power of the motor doesn’t exceed
1Kwatt.
E3 Wrong writing to memory
Problem writing parameters in
memory
Turn o the board and try again. If
the problem occurs again, replace
the board; the memory is damaged.