OPERATING PROCEDURES
6-5
Model 104
Operating Procedures
6
5. Put the control switch into the EJECT position.
This causes the sanitizing solution in the freezing
cylinder to be agitated. Allow it to agitate for five
minutes.
WARNING! Keep fingers out of fill and
discharge openings. Failure to do so may result in
personal injury or component damage.
Figure 6-20
6. Put the control switch into the off position.
7. Hold a pail beneath the ejection port, open the draw
arm, and drain the sanitizing solution from the
freezing cylinder.
8. Close the draw arm.
Figure 6-21
Priming
1. With the control switch in the off position, hold an
empty pail beneath the ejection port and open the
draw arm.
WARNING! Keep fingers out of fill and
discharge openings. Failure to do so may result in
personal injury or component damage.
2. Pour the desired amount of mix into the funnel. The
mix in the freezing cylinder will force out any
remaining sanitizing solution.
3. When full-strength mix is flowing from the ejection
port, close the draw arm.
Figure 6-22
4. Set the timer for the time required for the batch. Allow
the unit to operate until the buzzer sounds and the
refrigeration system automatically cycles off.
Figure 6-23
5. Place the control switch in the AUTO position.