EasyManua.ls Logo

Taylor 430 - Page 55

Taylor 430
57 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Model 430 Torque
050367-12
08/14
Taylor Company
2014 Carrier Commercial Refrigeration, Inc.
c
W1
MIX OUT SENSITIVITY: REMOVE JUMPER TO
REDUCE SENSITIVITY.
YES
W2
MIX LOW SENSITIVITY: REMOVE JUMPER TO
REDUCE SENSITIVITY.
YES
GRN/YEL
WHT
BLK
BLK
BLK BLK
GROUND FRAME SECURELY
M
T2
COMPRESSOR
L2L1 T1
COMPRESSOR
CONTACTOR
CONDENSER
FAN MOTOR
BEATER
MOTOR
OVERLOAD
SWITCH
COMPRESSOR
HIGH PRESSURE
LIMIT SWITCH
(SEE FIG 1)
BLK
BLK
COMPRESSOR
CONTACTOR
BLK WHT WHT
M
BLK BLK
WHT
WHT
L1
L1
N
AUTO
WASH
OFF
AUTO
WASH
OFF
BLK
POWER
SWITCH
BLK BLK BLU
M
BEATER
MOTOR
L2L1
BEATER MOTOR
STARTER
(SEE FIG 2)
BLK
BEATER MOTOR
STARTER
BLK WHT WHT
ONE SIDE OF A
TWO WIRE CORD
ONE SIDE OF A
TWO WIRE CORD
T1 T2
BLK
GRN/YEL
MIX
LOW
PROBE
WHT/BLU
MIX
OUT
PROBE
RED/BLK
BLK/WHT
ORG
WHT
NO
NC
DRAW
SWITCH
C0M
WHTWHTWHTORG
BEATER MOTOR
STARTER COIL
BRN/WHT WHT WHT
COMPRESSOR
CONTACTOR COIL
ADD MIX
LAMP
CLEAN REQ'D
LAMP(OPTIONAL)
ORG/WHT
BLU/WHT
WHT
WHT
WHT
NOTE:
STATIC ELECTRICITY MAY CAUSE DAMAGE TO SOLID
STATE COMPONENTS. ELIMINATE STATIC ELECTRICITY
BY TOUCHING GROUNDED UNIT BEFORE HANDLING SOLID
STATE COMPONENTS.
BLK L1
WHT NEUTRAL
LINE
5 2
4 1
RELAY
START
CAPACITOR
RUN
CAPACITOR
WHT
R
BLK
BRN
BLK
BLU
BLEED RESISTOR
BRN
S
TECUMSEH COMPRESSOR CONNECTION SCHEMATIC
BLKBLK
C
COMPRESSOR
OVERLOAD
GRN/YEL
GRN/YEL
GRN/YEL
GRN/YEL
GRN/YEL
GRN/YEL
GRN/YEL
GRN/YEL
1
4
5
6
BLK L1
WHT NEUTRAL
LINE
YEL/BLK
RED
BLU
YEL
BLK
MAGNETEK BEATER MOTOR CONNECTION SCHEMATIC
COUNTER CLOCKWISE ROTATION
FACING LEAD END
WHT
BLK/WHT BLK/WHT
BLK
GRN/YEL
95 96
L2 BTRCOMP
NO
C
NO
C
1 2 3 4 5 6 7 8
J3
1
2
3
4
5
6
7
1
2
3
4
5
6
7
8
ORG
NO
NC
TORQUE
SWITCH
C0M
GRN/YEL
WHT
CORCOM
FILTER
(SPINNER)
CORCOM
FILTER
MIX OUT
LAMP
WHT
RED/WHT
J1
J5
NO
NC
DOOR
SWITCH
(OPTIONAL)
C0M
FIG.1
FIG.2
BRN/WHT
BLK/WHT
YEL
WHT/BLK
BRN
WHT/RED
M
NC
NO
SPINNER
SWITCH
C0M
WHTWHTWHT
BLK
BLK
SPINNER
GRAY/WHT
GRAY
WHT/ORN
WHT
BLU
BLK
BLK
BLU
RED
240V
24VAC
AGITATOR
TRANSFORMER
M
WHT
WHT
AGITATOR
MOTOR
AGITATOR
RUN CAPACITOR
AGITATOR-OPTION
BLK
READY LAMP
(OPTIONAL)
PRP/WHT
6
1
2
J2
115V
240V
SET SWITCH
TO 115V
A2
A1
WHT/PRP
- +
NO
NC
DRAW
SWITCH
C0M
PANEL
JACK
ADDITIONAL DRAW SWITCH
OPTIONAL FOR FLAVORBURST
T1 OR BLU
T8 OR RED
THERMAL OL
BRN
BLK L1
WHT NEUTRAL
4
2
T4 OR YEL
T5 OR BLK
A
P2 OR BRN
P1 OR PUR
MAIN
START
5
1
GE/RBC BEATER MOTOR WIRING
CCWLE-RED OR T8 INTERNAL ON #5,BLACK OR T5 INTERNAL ON #A}
1
2
3
TORQUE CONTROL JUMPER FUNCTION
JUMPER FACTORY
INSTALLED
J1 PINS 1&2
45° LOCKOUT-INSTALL JUMPER TO ENABLE
(REQUIRES OPTIONAL DOOR SWITCH)
NO
J2 PINS 1&2
REFRIGERATION INTERVAL. NO JUMPER = 7
MINUTES, JUMPER INSTALLED = 12 MINUTES.
NO
J2 PINS 3&4
1-DAY LOCKOUT. INSTALL JUMPER TO ENABLE.
(REQUIRES OPTIONAL DOOR SWITCH)
NO
J2 PINS 5&6
4-DAY LOCKOUT. INSTALL JUMPER TO ENABLE.
(REQUIRES OPTIONAL DOOR SWITCH)
CUSTOMER
SPECIFIC
TORQUE CONTROL
IF 4 DAY LOCKOUT
IS REQUIRED, MOVE
JUMPER ONTO PINS
5&6
LINE
LOAD
BLK
WHT
GRN/YEL
F1
W2
W1
FUSE

Related product manuals