OPERATING PROCEDURES
6-7
Model 8756
Operating Procedures
6
4. Check the small hole in the air orifice to ensure it is
not clogged. Place the air orifice into the top of the
piston.
Figure 6-24
5. Lightly lubricate the inside of the pump body, top and
bottom.
Figure 6-25
6. Insert the piston, air orifice end first, into the pump
body and push upward.
Figure 6-26
Important! The drive hole in the piston must be visible
through the hole in the pump body.
Figure 6-27
7. Insert the two check bands and the two O-rings onto
the grooves on the liquid valve body. Do not lubricate
the check bands or O-rings.
Figure 6-28
8. Insert the liquid valve body by aligning the steel
button at the base of the liquid valve body with the
cut-out groove at the bottom of the pump body.