6-10
OPERATING PROCEDURES
Model 8756
Operating Procedures
6
3. Brush-clean the mix inlet tube with the long brush
and the sanitizing solution.
Figure 6-39
4. Connect the free end of the flare line to the threaded
fitting on the mix inlet tube.
Figure 6-40
5. Attach the quick disconnect fitting of the pressure line
to the other fitting on the mix inlet tube. Allow the
other end to hang free.
Figure 6-41
6. Insert the free end of the suction line and the
pressure line into the pail of sanitizing solution.
Figure 6-42
7. Place the power switch in the ON position.
8. Press the PUMP key. A light will illuminate, indicating
that the air/mix pump is operating. This action will
cause the sanitizing solution to be pumped through
the air/mix pump and through the pressure line. After
approximately 15 seconds, press the PUMP key. The
light will shutoff, and the pump will stop operation.
Figure 6-43