OPERATING PROCEDURES
6-11
Model 8756
Operating Procedures
6
9. Drain the pressure line. Connect the free end of the
pressure line to the pressure switch.
Figure 6-44
10. Place an empty pail under the door spout, and raise
the prime plug.
Figure 6-45
11. Press the WASH and PUMP keys. The indicator
lights will illuminate, indicating pump and beater
motor operation.
Figure 6-46
12. When a steady stream of sanitizing solution is flowing
from the prime plug hole in the bottom of the freezer
door, press the PUMP key. This will de-activate the
pump operation. Push down the prime plug and allow
the beater to agitate for 5 minutes.
Figure 6-47
13. After 5 minutes, open the prime plug. Press the
PUMP key. Open the draw valve and draw off the
remaining sanitizer. Momentarily open the center
draw handle to sanitize the center door spout.
Figure 6-48
13038p