42
Model H60Troubleshooting Guide
PROBLEM PROBABLE CAUSE REMEDY
PAGE
REF.
13. No freezer operation after
placing unit in the AUTO
mode.
a. Unit unplugged. a. Plug into wall receptacle. ---
b. Circuit breaker off or
blown fuse.
b. Turn circuit breaker on or
replace fuse.
---
c. Beater motor out on reset. c. Clear the tone and reset
freezer.
13
d. Compressor of f on high
pressure cut out.
d. Clear the tone. Place unit
in the AUTO mode. If
problem persists, contact
service technician.
17
e. Water turned off
(water- cooled units.)
e. Re- establish water
supply.
---
14. W ater continues to flow
through spinner housing.
a. Rinse solenoid stuck
open.
a. Call service technician for
repair .
---
15. Spinner shaft will not
rotate to blend syrup into
product.
a. Flexible cable broken. a. Call service technician to
replace cable.
---
b. Pin missing in female
quick disconnect.
b. Call service technician to
replace disconnect.
---
16. Liquid Crystal Display is
blank after power switch is
placed in the ON position.
a. Unit unplugged. a. Plug into wall receptacle. ---
b. Circuit breaker off or
blown fuse.
b. Turn circuit breaker on or
replace fuse.
---
c. Screen intensity out of
adjustment.
c. Call service technician to
adjust.
---
17. Product not feeding into
freezing cylinder.
a. Inadequate mix in hopper. a. Fill hopper with mix. 27
b. Mix inlet hole frozen up. b. Hopper temperature
needs adjustment. Call
service technician.
---
c. Assembled air tubes
installed incorrectly.
c. Install in mix inlet hole,
using end with the hole in
it. Pin on inner air tube
must be positioned at the
bottom of the notch in the
outer air tube.
28