MPPT charge controller User Manual
>Parameter Set
>Para_System
Display Setting range Description
SYS_Module_Addr 1~4;Default setting:1
Modul parallal address in
system.
DC_Coupling_EN
0-Disable
1-Enable
Default setting: 0-Disable
Enable state of DC
coupling system mode,
read only. Automatic
enablement when forming
a DC coupling system with
kinergier.
>Para_Mode
Display Setting range Description
OutCtrl_CHG
0- Disable
1- Enable
Default setting: 0-Disable
Enable state of charging
external control mode,
read only.
RlyCtrl_Config
0-Default
1- Alarm Switch
Default setting: 0- Default
Output dry contact
configuration.Select 0, if
the connection is detected
in the DC Coupling
system, take one puff
every 5 minutes to wake
up Kinergier
Pro(Connected to the
input dry contacts of the
Kinergier Pro).
Select1,short connection
at fault alarm.
Silent_Mode_EN
0- Disable
1- Enable
Default setting: 0-Disable
Silent mode setting
Force_Charge
0-Disable
1-Force CHG 24V OR 48V
Default setting: 0-Disable
Forced charge mode
setting
>Para_System
Para_Mode
>Para_Battery
Change Password
>Setup Wizard
Reset Parameter
>Clear
EnergyLog