RQT7231
3
WARNING:
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR
PRODUCT DAMAGE, DO NOT EXPOSE THIS APPARATUS
TO RAIN, MOISTURE, DRIPPING OR SPLASHING AND
THAT NO OBJECTS FILLED WITH LIQUIDS, SUCH AS
VASES, SHALL BE PLACED ON THE APPARATUS.
This product may receive radio interference caused by
mobile telephones during use. If such interference is
apparent, please increase separation between the product
and the mobile telephone.
THIS UNIT IS INTENDED FOR USE IN MODERATE CLIMATES.
CAUTION!
DO NOT INSTALL OR PLACE THIS UNIT IN A
BOOKCASE, BUILT-IN CABINET OR IN ANOTHER
CONFINED SPACE. ENSURE THE UNIT IS WELL
VENTILATED. TO PREVENT RISK OF ELECTRIC SHOCK
OR FIRE HAZARD DUE TO OVERHEATING, ENSURE
THAT CURTAINS AND ANY OTHER MATERIALS DO
NOT OBSTRUCT THE VENTILATION VENTS.
DO NOT OBSTRUCT THE UNIT’S VENTILATION
OPENINGS WITH NEWSPAPERS, TABLECLOTHS,
CURTAINS, AND SIMILAR ITEMS.
DO NOT PLACE SOURCES OF NAKED FLAMES, SUCH
AS LIGHTED CANDLES, ON THE UNIT.
DISPOSE OF BATTERIES IN AN ENVIRONMENTALLY
FRIENDLY MANNER.
(For United Kingdom)
(“EB” area code model only)
For your safety, please read the following text carefully.
This appliance is supplied with a moulded three pin mains plug for
your safety and convenience.
A 5-ampere fuse is fitted in this plug.
Should the fuse need to be replaced please ensure that the
replacement fuse has a rating of 5-ampere and that it is approved
by ASTA or BSI to BS1362.
Check for the ASTA mark m or the BSI mark o on the body of the fuse.
If the plug contains a removable fuse cover you must ensure that it
is refitted when the fuse is replaced.
If you lose the fuse cover the plug must not be used until a
replacement cover is obtained.
A replacement fuse cover can be purchased from your local dealer.
If a new plug is to be fitted please observe the wiring code as
stated below.
If in any doubt please consult a qualified electrician.
IMPORTANT
The wires in this mains lead are coloured in accordance with the
following code:
Blue: Neutral, Brown: Live.
As these colours may not correspond with the coloured markings
identifying the terminals in your plug, proceed as follows:
The wire which is coloured Blue must be connected to the terminal
which is marked with the letter N or coloured Black or Blue.
The wire which is coloured Brown must be connected to the terminal
which is marked with the letter L or coloured Brown or Red.
WARNING: DO NOT CONNECT EITHER WIRE TO THE
EARTH TERMINAL WHICH IS MARKED WITH THE
LETTER E, BY THE EARTH SYMBOL
nn
nn
n OR COLOURED
GREEN OR GREEN/YELLOW.
THIS PLUG IS NOT WATERPROOFKEEP DRY.
Before use
Remove the connector cover.
How to replace the fuse
The location of the fuse differ according to the type of AC mains
plug (figures A and B). Confirm the AC mains plug fitted and follow
the instructions below.
Illustrations may differ from actual AC mains plug.
1. Open the fuse cover with a screwdriver.
2. Replace the fuse and close or attach the fuse cover.
Caution for AC Mains Lead
CAUTION!
IF THE FITTED MOULDED PLUG IS UNSUITABLE FOR
THE SOCKET OUTLET IN YOUR HOME THEN THE FUSE
SHOULD BE REMOVED AND THE PLUG CUT OFF AND
DISPOSED OF SAFELY.
THERE IS A DANGER OF SEVERE ELECTRICAL SHOCK
IF THE CUT OFF PLUG IS INSERTED INTO ANY 13-
AMPERE SOCKET.
Fuse
(5 ampere)
Fuse
(5 ampere)
Figure A
Figure B
Fuse cover
Figure A
Figure B
The socket outlet shall be installed near the equipment and
easily accessible or the mains plug or an appliance coupler
shall remain readily operable.
Although the AC power switch is in the OFF position, the
unit is not completely disconnected from the mains. Remove
the plug from the main electrical outlet if you will not be
using the unit for an extended period of time. Place the unit
so the plug can be easily removed.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Technics SH-MZ1200 and is the answer not in the manual?

Technics SH-MZ1200 Specifications

Input Sensitivity and Impedance IconInput Sensitivity and Impedance
PHONO input sensitivity2.5 mV
PHONO input impedance47 kΩ
LINE input sensitivity250 mV
LINE input impedance10 kΩ
EFFECT RETURN input sensitivity250 mV
EFFECT RETURN input impedance47 kΩ
MIC input sensitivity0.7 mV
MIC input impedance1 kΩ
Output Voltage and Impedance IconOutput Voltage and Impedance
MASTER 1, 2 (RCA) output voltage1 V
MASTER 1, 2 (RCA) output impedance600 Ω
MASTER 1 (XLR) output voltage1 V
MASTER 1 (XLR) output impedance600 Ω
MONITOR output voltage1 V
MONITOR output impedance1 kΩ
REC OUT output voltage250 mV
REC OUT output impedance1 kΩ
EFFECT SEND output voltage250 mV
EFFECT SEND output impedance1 kΩ
Headphone output power30 mW
Headphone output impedance32 Ω
Frequency Response IconFrequency Response
MASTER 1, 2 frequency response20 Hz to 20 kHz
REC OUT frequency response20 Hz to 20 kHz
EFFECT RETURN frequency response20 Hz to 20 kHz
MIC frequency response20 Hz to 20 kHz
Digital Audio IconDigital Audio
Coaxial digital input compatible sampling rate48 kHz/44.1 kHz/32 kHz
Coaxial digital output sampling rate44.1 kHz
Equalizer Characteristics IconEqualizer Characteristics
CD/LINE/PHONO LOW EQ gain+12 dB, –24 dB (50 Hz)
CD/LINE/PHONO MID EQ gain+12 dB, –24 dB (1 kHz)
CD/LINE/PHONO HIGH EQ gain+12 dB, –24 dB (10 kHz)
MIC LOW EQ gain+12 dB, –24 dB (100 Hz)
MIC HIGH EQ gain+12 dB, –24 dB (10 kHz)
General IconGeneral
Power supplyAC 230-240 V, 50 Hz
Power consumption35 W
Dimensions (WxHxD)300 mm x 103 mm x 330 mm
Mass5.3 kg