Instruction Manual ITEM TE700 TECNA S.p.A.
24/128
TABLE WITH CONSTANT CURRENT OPERATING MODE PARAMETERS
PARAMETER RANGE VALUE
PROGRAM N. 001 – 300
WORKING MODE IK
CONTROL MODE * NO
QUALITY – T* OFF
QUALITY – R * OFF
SQUEEZE 1 0.5 – 99.0 cycles
SQUEEZE 00.0 – 99.0 cycles
PRESSURE 00.5 – 10.0 bar
FORGE DELAY 00 – 99 cycles
FORG.PRESS. 00.5 – 10.0 bar
PRE-WELD 0000 – 1000 mS
PRE-CURR. 000.30 – 200.00 KA
COLD 1 0000 – 1000 mS
SLOPE UP 0000 – 1000 mS
WELD 0001 – 2000 mS
CURRENT 000.30 – 200.00 KA
COLD 2 0000 – 1000 mS
IMPULSE N. 1 – 9
WELD 2 0000 – 1000 mS
CURRENT 2 000.30 – 200.00 KA
SLOPE DOWN 0000 – 1000 mS
COLD 3 0000 – 1000 mS
POST-WELD 0000 – 1000 mS
POST-CURR. 000.30 – 200.00 KA
HOLD TIME 00.5 – 99.0 cycles
OFF TIME 00.0 – 99.0 cycles
CONTROL MODE * CUR
LIM I MIN 000.30 – 200.00 KA
LIM I MAX 000.30 – 200.00 KA
CONTROL MODE * RO
LIM RO MIN 005.0 – 100.0%
LIM RO MAX 005.0 – 100.0%
CONTROL MODE * VE
LIM V MIN 00.20 – 20.00 V
LIM V MAX 00.20 – 20.00 V
CONTROL MODE * PW
LIM P MIN 000.20 - 600.00 KW
LIM P MAX 000.20 – 600.00 KW
CONTROL MODE * ENE
LIM E MIN 00000 – 60000 J
LIM E MAX 00000 – 60000 J