TECNA S.p.A. ITEM TE700 Instruction Manual
STOP BAD SPOT T1
The STOP BAD SPOT T1 parameter allows the operator to program the control unit so that it
stops when welds are carried out with weld programs associated with tool number 1 with
values of the controlled parameter beyond the set limits.
The programmed value indicates the number of consecutive "out of limits" welds that cause
the machine to stop. The limits error occurs when a welding is carried out with values that are
greater than or less than the set limits. Adjust the value with keys and from 0 to 15.
When the value is set to zero the function is disabled therefore the condition in which the
preset limits are exceeded does not stop the welder.
For further information, please, check the relevant paragraph.
STOP BAD SPOT T2
The STOP BAD SPOT T2 parameter allows the operator to program the control unit so that it
stops when welds are carried out with weld programs associated with tool number 2 with
values of the controlled parameter beyond the set limits.
The programmed value indicates the number of consecutive "out of limits" welds that cause
the machine to stop. The limits error occurs when a welding is carried out with values that are
greater than or less than the set limits. Adjust the value with keys and from 0 to 15.
When the value is set to zero the function is disabled therefore the condition in which the
preset limits are exceeded does not stop the welder.
For further information, please, check the relevant paragraph.
STOP BAD SPOT T3
The STOP BAD SPOT T3 parameter allows the operator to program the control unit so that it
stops when welds are carried out with weld programs associated with tool number 3 with
values of the controlled parameter beyond the set limits.
The programmed value indicates the number of consecutive "out of limits" welds that cause
the machine to stop. The limits error occurs when a welding is carried out with values that are
greater than or less than the set limits. Adjust the value with keys and from 0 to 15.
When the value is set to zero the function is disabled therefore the condition in which the
preset limits are exceeded does not stop the welder.
For further information, please, check the relevant paragraph.
STOP BAD SPOT T4
The STOP BAD SPOT T4 parameter allows the operator to program the control unit so that it
stops when welds are carried out with weld programs associated with tool number 4 with
values of the controlled parameter beyond the set limits.
The programmed value indicates the number of consecutive "out of limits" welds that cause
the machine to stop. The limits error occurs when a welding is carried out with values that are
greater than or less than the set limits. Adjust the value with keys and from 0 to 15.
When the value is set to zero the function is disabled therefore the condition in which the
preset limits are exceeded does not stop the welder.
For further information, please, check the relevant paragraph.
LANGUAGE
With this parameter the operator programs the language in which the control unit should
display both the parameters to be set and the error messages.
One may select the following languages: ITALIAN – ENGLISH – SPANISH – GERMAN –
FRENCH – HUNGARIAN – PORTUGUESE – SWEDISH.