BLAST CHILLER ISTRUCTION C-200306/2011
•
If at the end of the maximum blast chilling interval the core
probe continues to display a temperature higher than the
value for the end of blast chilling, the displays will indicate
an alarm for excessively long chilling (ALL 14) alternating with
the temperature and time; at the same time, the alarm beep
w
ill be activated.
The blast chilling cycle continues until the end chilling tem-
perature has been reached; display
h
counts back the min-
utes remaining until the end of the cycle.
N
ota: press push-button
i
t
o mute the alarm; press push-but-
ton again to clear the alarm display.
• At the end of the chilling cycle, the appliance automatically
switches to the set storage temperature for an indefinite in-
terval (like a standard storage appliance).
Nota: LEDs
f
switch off while LEDs
g
light up.
• The cell temperature is constantly shown on display
j
; dur-
ing this cycle, defrost cycles are performed at regular inter-
vals with duration set as required (parameter programming
reserved for installation technician). The factory setting for
positive storage temperature is +2°C.
• Press push-button
y
to set the appliance to STOP status
(relative LED switches off ), ready for a new cycle.
• To modify the final blast chilling temperature, consult the
user programming instructions.
4.4 SOFT TIMED BLAST CHILLING
• Press push-button
w
(relative LED lights up), then press
push-button
t
to select the timer mode (LED
t
B on). Dis-
play
h
shows the maximum chilling time (set by default to
90 minutes).
To modify this time, press push-buttons
u
and
i
(time in
minutes).
• Press push-button
y
to start the appliance. LED
t
B and
push-button LEDs remain on and LEDs
f
flash throughout
the cycle.
• Internal cell temperature is shown on display
j
.
• When the maximum chilling time has counted back to 0, the
chilling cycle is completed and the appliance automatically
switches to the set positive storage temperature for an in-
definite interval.
• LEDs illuminate and the beep is activated when the cycle is
finished (as in the chilling cycle by temperature). The same
applies for the positive storage function.
Press push-button
y
to set the appliance to STOP status
(relative LED switches off ), ready for a new cycle.
Use the storage function sparingly. After chilling, food
products should be placed in storage cabinets.
4
.5 HARD BLAST CHILLING FEATURES
When the HARD function is used, chilling takes place in two
stages:
• an initial “Hard” stage when the air temperature is brought
down to below 0°C in order to accelerate chilling;
•
a second“Soft”stage, involving air temperatures around 0°C.
4.6 HARD BLAST CHILLING BY TEMPERATURE
• Press push-button
e
(relative LED lights up), then press
p
ush-button
t
t
o select the temperature mode (LED
t
A
on). Insert the core probe into the core of the product to be
chilled.
• Start up the cycle by pressing push-button
y
. LED
t
A and
those relative to the push-buttons pressed illuminate
throughout the cycle, while LEDs
f
flash.
• Display
h
indicates the maximum blast chilling time (start-
ing temperature to end of the blast chilling temperature -
factory setting - 90 minutes).
• The temperature measured by the core probe is shown by
display
j
.
• The instrument timer starts the countdown of the maximum
blast chilling time as soon as the temperature measured by
the core probe falls below the temperature of +65°C (the dot
at the bottom right of display
h
flashes).
• Once the cycle has been started, the appliance operates ini-
tially with an air temperature below 0°C (LED on push-button
e
flashes), then with temperatures around 0°C (LED on
push-button
e
on).
Nota: the first stage of the cycle is completed when the core
probe detects a temperature of +20°C in the product core.
• The blast chilling phase ends only when the core probe (in-
serted in the product core) indicates that the set blast chill-
ing temperature (+3°C) has been reached as signalled by an
intermittent beep for a minute. During the beep, LEDs
f
and
g
flash.
Display
j
indicates the temperature inside the cell, while
display
h
shows blast chilling time reset to zero.
• The alarm (ALL 14) and conservation functions cut in with
relative indicators in the same way as for timed Soft blast
chilling.
• Press push-button
y
to set the appliance to STOP status