BLAST CHILLER ISTRUCTION C-200306/2011
2. INSTALLATION
2.1 DATA PLATE INFORMATION
•
Check that the data specified on the plate correspond to the
characteristics of the power supply (V, kW, Hz, no. phases and
power available).
• The dataplate with appliance specifications is located at the
rear exterior of the machine and/or on the electrical boards.
The set-up of individual
units and the installation of
condensers are subject to
the fire-safety regulations of
the country in which the
machine is installed; seek all
necessary advice from the
local fire-fighting authori-
ties.
Bear in mind that the intervention of safety valves or plug
fuses in the refrigerating circuit will lead to the immediate
discharge of refrigerant into the environment.
2.2 REMARKS / MALFUNCTION’S CLAIMS
In case of machine malfunctioning and claim on Blast Chil-
lers delivered in the following way :
• Assembled MOD.
w
We ask you to indicate to the dealer / service: machine
model, machine code number and apparatus serial number.
These information are written on the registration label, in-
stalled on the back of machine and inside the door.
• Disassembled MOD. t
We ask you to indicate to the dealer / service: machine
model, machine code number and apparatus serial number.
These information are written on the registration label, in-
stalled on top of the control panel.
2.3 POSITIONING
• The machine must be installed and commissioned in com-
plete compliance with safety regulations, procedures and
standing laws.
• The installation technician bears the responsibility of ensu-
ring compliance with fire safety requirements; seek all ne-
cessary advice from the local fire-fighting authorities.
• Position the machine in the allocated site.
• Adjust the machine feet until the appliance is perfectly level.
In the case of particularly heavy equipment, use appropriate
lifting means (fig. A - Cap. 1.3).
• If the appliance is not perfectly level, correct operation and
condensate flow-off will not be assured.
Avoid
• direct exposure to sunlight;
•
closed sites with high temperatures and poor air circulation;
• installing the machine near sources of heat.
2.4 AMBIENT TEMPERATURE AND AIR CIRCULATION
For air-cooled appliances, the maximum ambient tempera-
ture for operation is 32°C. Correct operation cannot be gua-
ranteed at higher temperatures.
The machine may operate safely to a maximum temperature
of 38°C.
Remote condensing units must be installed in special rooms
or outdoors, protected against direct sunlight by a shelter or
roof structure (at the cost of the purchaser).
Sufficient air circulation must be guaranteed at all times.
2.5 ELECTRICAL CONNECTIONS
A dedicated thermal-magnetic circuit breaker compliant
with established regulations must be installed on the ap-
pliance power line.
• Connected electrical cables must correspond to the techni-
cal data (as specified on electrical drawings provided by the
installation technician).
Connect the earthing conductor to an efficient earthing sy-
stem.
The manufacturer declines all liability and guarantee obli-
gations in the event of injury to persons or damage to
equipment and objects due to incorrect installation and/or
failure to comply with standing installation regulations.
2.5.1 Connecting the appliance to the power supply
In the event of damage to the power supply cable on the ap-
pliance, have the cable replaced only by a qualied electri-
cian to avoid any risk of personal injury
THESE OPERATIONS MUST BE
PERFORMED BY A CERTIFIED
INSTALLATION TECHNICIAN ONLY