Group 08: Protection Parameters
Code
Parameter
Name
Setting Range Default
Attrib
ute
when Reaching
the Set
Frequency.
2: Start to Detect
when the
Operation is
Begun.
08-14
Selection of
Over-Torque
Operation
0: Deceleration
to Stop when
Over Torque is
Detected.
0
1: Display
Warning when
Over Torque is
Detected. Go on
Operation.
2: Coast to Stop
when Over
Torque is
Detected
08-15
Level of Over-
Torque
Detection
0~300 150
08-16
Time of Over-
Torque
Detection
0.0~10.0 0.1
08-17
Selection of
Low-Torque
Detection
0: Low-Torque
Detection is
Disabled.
0
1: Start to Detect
when Reaching
the Set
Frequency.
2: Start to Detect
when the
Operation is
Begun.
08-18
Selection of
Low-Torque
Operation
0: Deceleration
to Stop when
Low Torque is
Detected.
0
1: Display
Warning when
Low Torque is
Detected. Go on
Operation.
2: Coast to Stop
when Low
Torque is
Detected
08-19
Level of Low-
Torque
Detection
0~300 30
08-20
Time of Low-
Torque
Detection
0.0~10.0 0.1
08-21
Limit of Stall
Prevention in
Acc over
1~100 50
Group 08: Protection Parameters
Code
Parameter
Name
Setting Range Default
Attrib
ute
Base Speed
08-22
Stall
Prevention
Detection
Time in
Operation
2~100 100
08-23
Ground Fault
(GF)
Selection
0: Disable
0
1: Enable
08-24
External Fault
Operation
Selection
0: Deceleration
to Stop
0 1: Coast to Stop
2: Continuous
Operation
08-25
Detection
Selection of
External Fault
0: Immediately
Detect when the
Power is Supplied.
0
1: Start to Detect
when the
Operation is
Started.
08-26
~
08-29
Reserved
08-30
Run
Permissive
Function
Selection
0: Deceleration
to Stop
0
1: Coast to Stop
08-31
~
08-34
Reserved
08-35
Motor
Overheating
Fault
Selection
0: Disable
0
1: Deceleration
to Stop
2: Free Run to t op
3: Continue
Running
08-36
PTC Input
Filter Time
Constant
0.00 ~ 5.00 2.00
08-37
Fan Control
Function
0: Start in
operation
0
1: Permanent
Start
2: Start in high
temperature
(Note)
08-38
Delay Time of
Fan Off
0~600 60
08-39
Delay Time of
Motor
Overheat
Protection
1~300 60
08-40
Motor2
Acceleration
Stall
Prevention
Level
20~200
HD:150
ND:120
08-41
Motor2
Acceleration
1~100 50