44
Parameter Name & Function Default Unit
Setting
Range
Control
Mode
Chapter
Speed command smooth accel/decel time
Constant.
Sn206
Set Sn205=1 to enable this function then set the time
period for the speed to rise to 63.2% of the full speed.
1 msec
1
│
10000
S 5-3-6
Speed command linear accel/decel time constant.
Sn207
Set Sn205=2 to enable this function then set the time
period for the speed to rise linearly to full speed.
100
50
Rate Speed
Speed Command (%)
Speed Command
Sn207
Time (ms)
1 msec
1
│
50000
S 5-3-6