VOL
TS-mA/DIV-lnner
ring
(black
scale)
indicates
the
calibrated
voltage
or
current
vertical
deflection
factor
selected
for
oscilloscope
display
when
the
VOL
TS-mA/D
IV
VAR
control
is
in
the
CAL
detent.
Outer
ring
(blue
scale)
indicates
the
full scale range
selected
for
the
digital
multimeter
.
@
PWR
(BTRY)-Lights
when
instrument
is
on
and
suf-
ficient
battery
charge
is
available.
Light
extinguishes
when
battery
requires
recharging.
@
n-Selects
resistance
mode
for
digital
multimeter.
RMS
button
must
be
in
the
out
position
when
mea
-
suring
resistance
or
the
reading
accuracy
will be
de-
graded.
@
mA-Selects
current
mode
for
either
digital
multime-
ter
or
oscilloscope
function.
@
SEC/DIV-Selects
the
calibrated
sweep
rate
for
the
oscilloscope
when
the
HOR
IZ
MGF
VAR
control
is
in
the
CAL
detent.
Rear Panel
@ Integral Voltage
Probe-Used
by
both
the
DMM
and
oscilloscope
for
all voltage
measurements.
The
alli-
gator
clip
is
the
common
connection.
@ Insulated
Compartment-Used
to
store
the
power
line
plug
when
battery
operated.
-
@ Power
Cord-Used
when
instrument
is
to
be
operated
on
power
line voltage
or
the
batteries
are
being
char-
ged.
When
battery
operated,
the
power
line plug
Fig.
2-3.
Rear panel.
@
Operating I
nstructions-213
Service
should
be
stored
in
the
r
ear
panel
insulated
compart-
ment.
To
store
the
power
cord,
wrap
the
cord
in
the
direction
of
the
arrow
located
on
top
of
the
vinyl
cord
wrap
cover.
On
the
last
wrap,
store
the
plug in
the
insulated
compartment.
PROBE
STORAGE
To
store
the
probe,
lay
the
common
clip lead parallel
to
the
probe
lead,
and
attach
the
common
clip
to
the
probe
lead
with
the
small
plastic
clip
provided
on
the
common
clip.
Then
snugly
wrap
the
leads
in
the
direction
of
the
arrow
on
the
vinyl
cord
wrap
cover (see Fig. 2-
4).
When
the
common
clip
is
in
position
to
be
wrapped
into
the
bottom
side
of
the
storage
slot,
gently
press
the
common
clip
down
into
the
slot
(see Fig. 2-4)
and
continue
to
wrap
the
leads. As
the
wrap
is
completed,
carefully
guide
the
probe
into
its place
in
the
top
slot
of
the
vinyl
cover
(see Fig. 2-3)
and
gently
press
the
probe
down
into
the
slot.
90
-
136
VAC
48
-
62Hz
SW
[gl
DOUBLE
INSULATED
SAFETY
EARTH
NOT
REQUIRED.
CAUTION
HIGH
VOLTAGE
CONTAINED
INSIDE
REFER
SERVICE
TO
QUALIFIED
PERSONNEL
TH
IS INSTRUMENT
MfO
UNDER ONE Oft MO
RE
OF T
HE
fOllOWING
U $ l"AT£NT$ J
207
.
138
3,
197
,
752
l .
532
.
Hl
3.
59
.. ..24t
l
~~~:!:
p!J~:~1~:i:~·~~;f~~
1
:T:N;
3
:i},::E:;~;t''
R£00~$
'T TfJ<.TRONlX.INC .
ll.\VfRTOH
.OREGOH. MADE IN U.$.A
COMMON
CLIP
STORED
LOCATION
Fig.
2-4.
Probe storage.
..
PROBE
CHARACTERISTICS
ON 200-SERIES
INSTRUMENTS
I
I
1480
-
13
On
the
200
-series
instrument
probe(s),
each
probe
body
assembly
is
designed
to
meet
the
input
resistance
and
at-
tenuation
factor
for
the
specific
instrument
type.
These
assemblies are
not
interchangeable
between
all 200-series
instruments;
therefore,
when
more
than
one
type
of
in-
strument
is
being
repaired,
it
is
possible
for
the
wrong
probe
body
assembly
to
become
installed
on
the
probe.
Figure
2-5
shows
how
to
identify
the
assembly.
To
verify
that
the
proper
probe
body
assembly
is
installed
on
the
probe,
correlate
the
assembly
with
the
Tektronix
Part
Number
shown
in
Figure
2-5.
Then
compare
that
part
number
with
the
correct
probe
body
assembly
part
number
listed
in
the
Mechanical
Parts
List
section.
2-3